Rs-232C Configuration - Mitsubishi Electric MELSERVO MR-J2S- A Instruction Manual

General-purpose ac servo general-purpose interface servo amplifier
Table of Contents

Advertisement

14. COMMUNICATION FUNCTIONS

14.1.2 RS-232C configuration

(1) Outline
A single axis of servo amplifier is operated.
(2) Cable connection diagram
Wire as shown below. The communication cable for connection with the personal computer (MR-
CPCATCBL3M) is available. (Refer to Section 13.1.4.)
Personal computer
connector D-SUB9 (socket)
Note 1. Connector set MR-J2CN1 (3M)
Connector: 10120-6000EL
Shell kit: 10320-3210-000
2. 15m (49.2ft) or less in environment of little noise. However, this distance should be 3m (9.84ft) or less for use at 38400bps
or more baudrate.
Controller such as
personal computer
TXD
3
2
RXD
GND
5
7
RTS
CTS
8
6
DSR
4
DTR
Servo amplifier
MITSUBISHI
CHARGE
To CN3
RS-232C
(Note 2) 15m (49.2ft) or less
14 - 2
(Note 1)
Servo amplifier
CN3 connector
Plate
FG
2
RXD
1
GND
12
TXD
11
GND

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMr-j2s-*aMr-j2s- a seriesMr-j2s-20a

Table of Contents