5. PARAMETERS
Class No. Symbol
1
*OP1
Function selection 1
Used to select the input signal filter, pin CN1B-19 function and
absolute position detection system.
Name and function
Input signal filter
If external input signal causes chattering
due to noise, etc., input filter is used to
suppress it.
0:None
1:1.777[ms]
2:3.555[ms]
3:5.333[ms]
CN1B-pin 19's function selection
0:Zero Speed detection (ZSP)
1:Electromagnetic brake interlock (MBR)
CN1B-pin 18's function selection
0: Alarm (ALM)
1: Dynamic brake interlock (DB)
When using the external dynamic brake with 11kW
or more, make dynamic brake interlock (DB) valid.
Selection of absolute position detection system
(Refer to Chapter 15)
0: Used in incremental system
1: Used in absolute position detection system
5 - 6
Initial
Setting
Control
Unit
value
range
mode
0002
P S T
Refer to
Name
and
function.