5. PARAMETERS
Class No. Symbol
73
SC5
Internal speed command 5
Used to set speed 5 of internal speed commands.
Internal speed limit 5
Used to set speed 5 of internal speed limits.
74
SC6
Internal speed command 6
Used to set speed 6 of internal speed commands.
Internal speed limit 6
Used to set speed 6 of internal speed limits.
75
SC7
Internal speed command 7
Used to set speed 7 of internal speed commands.
Internal speed limit 7
Used to set speed 7 of internal speed limits.
76
TL2
Internal torque limit 2
Set this parameter to limit servo motor torque on the assumption
that the maximum torque is 100[%].
When 0 is set, torque is not produced.
77
For manufacturer setting
Do not change this value by any means.
78
79
80
81
82
83
84
Name and function
5 - 25
Initial
Setting
Control
Unit
value
range
mode
r/min 0 to in-
300
stanta-
neous
permi-
ssible
speed
r/min 0 to in-
500
stanta-
neous
permi-
ssible
speed
800
r/min
0 to in-
stanta-
neous
permi-
ssible
speed
100
%
0
P S T
to
100
00
10000
10
10
100
100
100
0000
S
T
S
T
S
T