Heat Sink Outside Mounting Attachment (Mr-Jacn) - Mitsubishi Electric MELSERVO MR-J2S- A Instruction Manual

General-purpose ac servo general-purpose interface servo amplifier
Table of Contents

Advertisement

13. OPTIONS AND AUXILIARY EQUIPMENT

13.1.11 Heat sink outside mounting attachment (MR-JACN)

Use the heat sink outside mounting attachment to mount the heat generation area of the servo amplifier
in the outside of the control box to dissipate servo amplifier-generated heat to the outside of the box and
reduce the amount of heat generated in the box, thereby allowing a compact control box to be designed.
In the control box, machine a hole having the panel cut dimensions, fit the heat sink outside mounting
attachment to the servo amplifier with the fitting screws (4 screws supplied), and install the servo
amplifier to the control box.
The environment outside the control box when using the heat sink outside mounting attachment should
be within the range of the servo amplifier operating environment conditions.
(1) Panel cut dimensions
Punched
hole
(2) How to assemble the attachment for a heat sink outside mounting attachment
Screw
(2 places)
D
4-M10 Screw
A
B
C
Attachment
MR-JACN15K
Changeable
dimension
A
Model
236
MR-JACN15K
(9.291)
326
MR-JACN22K
(12.835)
Screw
(4 places)
13 - 36
B
C
D
255
270
203
(10.63)
(7.992)
(10.039)
345
360
290
(13.583)
(14.173)
(11.417)
Attachment
MR-JACN22K
[Unit: mm(in)]
Servo amplifier
MR-J2S-11KA
MR-J2S-15KA
MR-J2S-22KA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMr-j2s-*aMr-j2s- a seriesMr-j2s-20a

Table of Contents