13. OPTIONS AND AUXILIARY EQUIPMENT
13.2.9 EMC filter
For compliance with the EMC directive of the EN Standard, it is recommended to use the following filter:
Some EMC filters are large in leakage current.
(1) Combination with the servo amplifier
Servo amplifier
MR-J2S-10A to MR-J2S-100A
MR-J2S-10A1 to MR-J2S-40A1
MR-J2S-200A MR-J2S-350A
MR-J2S-500A
MR-J2S-700A
MR-J2S-11KA
MR-J2S-15KA
MR-J2S-22KA
Note: Soshin Electric A surge protector is separately required to use any of these EMC filters. (Refer to the EMC Installation
Guidelines.)
(2) Connection example
(Note 1)
Power supply
Note 1. For 1-phase 230VAC power supply, connect the power supply to L
There is no L
for 1-phase 100 to 120VAC power supply.
3
2. Connect when the power supply has earth.
(3) Outline drawing
SF1252
149.5(5.886)
Recommended filter
Model
SF1252
SF1253
(Note) HF3040A-TM
(Note) HF3050A-TM
(Note) HF3060A-TMA
(Note) HF3080A-TMA
(Note) HF3100A-TMA
EMC filter
NFB
LINE
LOAD
L
L
1
1
L
L
2
2
L
L
3
3
(Note 2)
6.0(0.236)
L1
LINE
L2
L3
(input side)
L1'
LOAD
L2'
L3'
(output side)
8.5
16.0(0.63)
(0.335)
42.0
(1.654)
Leakage current [mA]
38
57
1.5
1.5
3.0
3.0
3.0
Servo amplifier
MC
L
1
L
2
L
3
L
11
L
21
,L
and leave L
1
2
SF1253
209.5(8.248)
13 - 52
Mass [kg]([lb])
0.75(1.65)
1.37(3.02)
5.5(12.13)
6.7(14.77)
10.0(22.05)
13.0(28.66)
14.5(31.97)
open.
3
L1
L2
L3
L1'
L2'
L3'
8.5
23.0(0.906)
(0.335)
49.0
(1.929)
[Unit: mm(in)]
6.0(0.236)
LINE
(input side)
LOAD
(output side)