8.34.2. LSU Skew Adjustment
< Example of Printed Image >
< Example of Printed Image >
Ver.2.1
Document Leading Edge
Document Leading Edge
(1) Remove the Front Left Cover.
(Refer to "Replacing the LSU", steps (1) ~ (15))
(2) Loosen 4 Red Screws.
Adjust the Lever Plate downwards and recheck the
Document Skewing. Readjust as needed.
One scale adjusts the skewed image by
approximately 0.01 mm.
Adjust the Lever Plate upwards and recheck the
Document Skewing. Readjust as needed.
390
DP-2310/3010
DP-2330/3030
MAR 2005