Panasonic DP-3030 Service Manual page 195

Digital imaging systems
Hide thumbs Also See for DP-3030:
Table of Contents

Advertisement

No.
47
Transfer Current Side 2
48
Not Used
49
T Mode Image Density
50
T/P Mode Image Density
51
P Mode Image Density
52
Not Used
53
CCD Read Position Adj
54
T Mode Contrast
55
T/P Mode Contrast
56
P Mode Contrast
57
Charge Roller Frequency
58
Charge Roller Current
59
Trail Edge Trans Trays
60
Trail Edge Trans Bypass
61
Trail Edge Trans 2Sided
62
TDC Gain Voltage Adjust
63
Lead Edge Read Timing
64
Side Edge Read Adjust
65
Black Density Reference
66
Black Density Output
67
ADF Image Density
68
Paper Loop (Tray 3)
69
Stamp Position Adjust
70-77 Not Used
78
Paper Loop (Tray 4)
79
MTF Adjust
80
QUANTUM Photo Mode Read
Ver. 2.1
Item
Adjustment of Transfer Current.
Image density adjustment for Text mode.
(-) : Darker.
(+) : Lighter.
Image density adjustment for Text/ Photo
mode.
(-) : Darker.
(+) : Lighter.
Image density adjustment for Photo mode.
(-) : Darker.
(+) : Lighter.
Adjustment of CCD read position.
Adjustment of Contrast for Text Mode.
Adjustment of Contrast for Text/Photo Mode.
Adjustment of Contrast for Photo Mode.
Adjustment of Charge Roller Frequency.
Adjustment of Charge Roller Current.
Trail Edge Transfer Image High Voltage
Timing Adjustment for Trays 1-4 feeding.
Trail Edge Transfer Image High Voltage
Timing Adjustment for Bypass Tray feeding.
Trail Edge Transfer Image High Voltage
Timing Adjustment for the 2nd side of 2-Sided
printing.
Adjustment of Toner Density sensor gain
voltage.
Adjustment of Lead Edge Read Point.
Adjustment of Side Edge Read Point.
Reference voltage for Black Density sensor.
Compensate value for Black Density sensor
output.
Compensation of ADF image density.
Individual Fine Adjustment for Tray 3
Adjustment of verification stamp position.
Individual Fine Adjustment for Tray 4
Adjustment of Scanning Sharpness by digital
image processing for Text /Photo Copy Mode.
Value of QUANTUM Gamma Table for Photo
Mode.
F6 Mode
Remarks
195
DP-2310/3010
DP-2330/3030
Setting
Range
-16 - +15
0.6uA
-99 - +99
-99 - +99
-99 - +99
-42 - +44
0.2mm
-128 - +127
-128 - +127
-128 - +127
-56 - +25
-58 - 0
5uA
-30 - +30
0.5mm
-30 - +30
0.5mm
-30 - +30
0.5mm
-10 - +10
0.033V
0 - +9
0.5mm
0 - +9
0.5mm
-127 - +127
-127 - +127
-99 - +99
-99 - +99
-50 - +50
0.3mm
-99 - +99
-2 - +2
+1 - +5
(Read Only)
MAR 2005

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-2330Dp-3010Dp-2310