Sign In
Upload
Manuals
Brands
Daikin Manuals
Heat Pump
FDYM03FAV1
Daikin FDYM03FAV1 Manuals
Manuals and User Guides for Daikin FDYM03FAV1. We have
3
Daikin FDYM03FAV1 manuals available for free PDF download: Service Manual, Operation Manual
Daikin FDYM03FAV1 Service Manual (502 pages)
SkyAir series Service Diagnosis
Brand:
Daikin
| Category:
Air Conditioner
| Size: 2 MB
Table of Contents
Table of Contents
2
1 List of Applicable Models
8
R-FU Series
8
R-GA Series
9
R-G Series
9
R-KU Series
10
R-LU Series
11
2 Symptom-Based Troubleshooting
36
2.1 Overview
36
Applicable Model
38
Supposed Causes
38
2.2 Equipment Does Not Operate
38
Troubleshooting
39
Indoor Unit Fan Operates, but Compressor Does Not Operate
40
Cooling / Heating Operation Starts but Stops Immediately
43
After Unit Shuts Down, It Cannot be Restarted for a While
45
Equipment Operates but Does Not Provide Cooling
48
Equipment Operates but Does Not Provide Heating
51
Equipment Discharges White Mist
54
Equipment Produces Loud Noise or Vibration
56
2.10 Equipment Discharges Dust
59
Remote Controller LCD Displays "88
60
3 Troubleshooting by Remote Controller
61
Procedure of Self-Diagnosis by Remote Controller
61
Wired Remote Controller
62
Hecking an Error or Warning
62
Wireless Remote Controller
63
Taking Corrective Action
63
3.2 Error Codes and Description
66
Outdoor Unit, System
69
Inverter Series
71
3.3 Detailed Error Codes
80
A0 Error of External Protection Device
86
Method of Error Detection
86
Error Decision Conditions
86
A1 Indoor Unit PCB Abnormality
88
A3 Drain Water Level System Abnormality
90
A6 Indoor Unit Fan Motor Abnormality
93
A6 Fan Motor (M1F) Lock, Overload
103
A7 Swing Flap Motor Abnormality / Lock
105
A8 Abnormal Power Supply Voltage
107
A9 Electronic Expansion Valve Coil (Y1E) Abnormality
109
AF Drain System Abnormality
112
AF Drain Level above Limit
114
AJ Capacity Setting Abnormality
115
Remote Controller Display
117
C1 Transmission Error (between Indoor Unit PCB and Fan PCB)
122
C1 Transmission Error (between Indoor Unit PCB and Adaptor PCB)
125
C4, C5, C9 Thermistor Abnormality
128
C6 Defective Combination (between Indoor Unit PCB and Fan PCB)
130
CC Humidity Sensor System Abnormality
132
CJ Remote Controller Thermistor Abnormality
135
E0 Actuation of Safety Device
137
E0 Activation of Outdoor Unit Protection Device
145
E1 Outdoor Unit PCB Abnormality
147
E3 High Pressure System Abnormality
150
E3 Abnormally High Pressure Level (HPS)
155
E3 High Pressure Abnormality (HPS)
157
E3 Actuation of High Pressure Switch
160
E4 Low Pressure System Abnormality
169
E4 Actuation of Pressure Sensor
171
E4 Actuation of Low Pressure Sensor
175
E4 Low Pressure System Abnormality
180
E5 Compressor Motor Lock
183
E6 Compressor Overcurrent
188
Approximate Input Current Value
190
E7 Outdoor Unit Fan Motor Abnormality
191
E9 Electronic Expansion Valve Abnormality
203
E9 Electronic Expansion Valve Coil Abnormality
207
F3 Discharge Pipe Temperature Abnormality
217
F3 Discharge Pipe Temperature Control
225
F6 Abnormal Heat Exchanging Temperature
227
F6 Refrigerant Overcharged
229
H3 High Pressure Switch Abnormality
231
H3 High Pressure Switch System Abnormality
236
H4 Low Pressure Sensor System Abnormality
238
H7 Outdoor Unit Fan Motor Signal Abnormality
242
H9, J3, J5, J6, J7, J8 Thermistor System Abnormality
244
H9 Outdoor Air Thermistor System Abnormality
246
J1 Pressure Sensor Abnormality
248
J2 Current Sensor System Abnormality
250
J3 Discharge Pipe Thermistor System Abnormality
252
J5 Suction Pipe Thermistor Abnormality
255
J6 Heat Exchanger Thermistor System Abnormality
257
J7 Liquid Pipe Thermistor Abnormality
259
J9 Subcooling Heat Exchanger Gas Pipe Thermistor Abnormality
261
JA High Pressure Sensor Abnormality
263
JC Suction Pipe Pressure Sensor Abnormality
266
L1 Outdoor Unit PCB Abnormality
268
L1 Outdoor Inverter PCB Abnormality
270
L1 Outdoor Unit PCB Abnormality
272
L4 Overcurrent of DC Output (Instantaneous)
275
L4 Radiation Fin Temperature Rise
277
Radiation Fin Temperature Detection Value
279
L5 Overcurrent of DC Output (Instantaneous)
285
L5 Momentary Overcurrent of Inverter Compressor
288
L5 Output Overcurrent Detection
291
L5 Inverter Compressor Abnormality
294
L5 Output Overcurrent Detection
297
(L8) Electronic Thermal Switch (Time Lag)
301
L8 Inverter Current Abnormality
304
L8 Inverter Compressor Overcurrent
307
L8 Electronic Thermal (Time Lag)
310
L9 Stall Prevention (Time Lag)
316
L9 Inverter Startup Error
318
LC Transmission Error between Inverter and Control PCB
324
LC Transmission Error (between Control PCB and Inverter PCB)
330
P1 Inverter Over-Ripple Protection
333
P1 Open Phase or Power Supply Voltage Imbalance
336
P4 Radiation Fin Thermistor Abnormality
338
P4 Radiation Fin Thermistor or Related Abnormality
342
PJ Defective Capacity Setting
343
PJ Error in Capacity Setting
345
PJ Field Setting Error after Replacing Main PCB or Defective Combination of PCB
346
PJ Defective Combination of Inverter and Fan Driver
348
PJ Defective Capacity Setting
350
U0 Refrigerant Shortage
354
U0 Low Pressure Drop Due to Refrigerant Shortage or Electronic Expansion Valve Failure
356
U0 Refrigerant Shortage
359
U1 Reverse Phase
365
U2 Insufficient Voltage
368
U2 Power Supply Voltage Abnormality
370
U2 Power Supply Insufficient or Instantaneous Failure
372
U2 Power Supply Voltage Abnormality
377
U3 Check Operation Is Not Executed
380
U4 or UF Transmission Error (between Indoor Unit and Outdoor Unit)
382
U4 Transmission Error between Indoor Unit and Outdoor Unit
388
U5 Transmission Error between Indoor Unit and Remote Controller
411
U7 Transmission Error between Outdoor Units
419
U8 Transmission Error between Main Remote Controller and Sub Remote Controller
422
U9 Transmission Error between Indoor and Outdoor Units in the same System
428
UA Defective Field Setting Switch
431
UA Improper Combination of Indoor and Outdoor Units, Indoor Units and Remote Controller
434
UA Field Setting Switch Abnormality
437
UA Field Setting Switch and Transmission Line Abnormality
440
UC Centralized Address Setting Error
444
UC Address Duplication of Centralized Controller
445
UE Transmission Error between Centralized Controller and Indoor Unit
446
UF Mis-Connection of Field Wiring
454
UF System Is Not Set yet
455
UF Transmission Error between Indoor and Outdoor Unit / Piping and Wiring Mismatch / Refrigerant Shortage
457
Outdoor Units
458
UF Transmission System Abnormality (between Indoor and Outdoor Units)
462
UH System Error, Refrigerant System Address Undefined
463
Check for Fan Motor Connector (Signal Line)
466
3.110 Check
466
Check for Fan Motor Connector (Power Supply Line)
467
Thermistor Resistance / Temperature Characteristics
468
Evaluation of Abnormal High Pressure
471
In Cooling Operation
471
In Heating Operation
472
Evaluation of Abnormal Low Pressure
473
Check for Power Transistor
475
Voltage Measuring Method
477
Pressure Sensor for Except RZQ(S)-B, RZQ-C7 and CMSQ
478
Pressure Sensor for RZQ(S)-B, RZQ-C7 and CMSQ
479
Electronic Expansion Valve Connector and Coil Resistance Criteria
480
Check for Factors Causing Wet Operation
481
Check for Excessive Refrigerant Charging
482
Check for Clogged Points
484
Check for Inadequate Refrigerant
485
Diagnosis of Inadequate Refrigerant
487
Fan Motor Pulse Check
489
Check for Causes of Rise in High Pressure
490
Check for Causes of Drop in Low Pressure
492
Method of Checking Inverter’s Power Transistors and Diode Modules
495
Electronic Circuit
496
Power Module Checking
497
Diode Module Checking
498
Broken Wire Check of the Connecting Wires
499
Warning
501
Advertisement
Daikin FDYM03FAV1 Service Manual (410 pages)
Super Multi Plus J Series
Brand:
Daikin
| Category:
Heat Pump
| Size: 12 MB
Table of Contents
Table of Contents
4
Introduction
10
Safety Cautions
10
Part 1 List of Function
14
List of Function
15
Function List for General
15
Function List for China
16
Function List for Taiwan
17
Function List for Europe
18
Function List for Singapore, Malaysia, Indonesia
19
Function List for Australia
20
Function List for Europe
21
Part 2 Specifications
22
Outdoor Units
23
Outdoor Unit
24
Indoor Unit
24
Heat Pump
27
BP Units
31
Indoor Units (for General)
32
Duct Connected Type
35
Indoor Units (for China)
47
Indoor Units (for Taiwan)
56
Indoor Units (for Europe)
65
Floor Standing Type
70
Part 3 Printed Circuit Board Connector Wiring Diagram and Name
72
Printed Circuit Board Connector Wiring Diagram and Name
73
Branch Provider Unit BPMK928B42, B43
73
Outdoor Unit RMK (X) 140JVMT (C) 9 (8), RMK140JAVM, RMX140JVMB, RMK (X) 140JZVMA (B)
74
Outdoor Unit RMK (X) 140JVMT (C) 9 (8), RMK140JAVM
74
Rmx140Jvmb, Rmk (X) 140Jzvma (B)
74
FTK25 / 35J Series, FTX25 / 35J Series, FTXD25 / 35K Series, FVX25 / 35K Series
77
FTK50~60HV Series, FTKD50~71JV Series, FTX50~60HV Series, FTXD50~71JV Series
79
CDX25~60HAV Series, CDK25~60HAV Series
81
FLK25~60HV Series, FLX25~60HV Series, FLK50 / 60JV Series, FLX50 / 60JV Series
83
FHYC35~71KV Series
86
FDYM60FA, FDYM03FA Series
88
Part 4 Main Functions Indoor Unit
90
Main Functions
91
Main Functions in Split Type
91
Fan Speed Control for Indoor Units
97
Program Dry Function
100
Night Set Mode
102
Intelligent Eye
103
Program Dry Operation
105
Freeze Protection Function
107
Powerful Operation
109
Skyair
111
Cautions When Skyair [Auto] [FAN] Are Used
113
Part 5 Main Functions Outdoor Unit / BP Unit
114
Refrigerant System and Function of Functional Parts of Outdoor Unit
116
Of Outdoor Unit
116
Major Functional Parts
117
Protective Devices, Thermistors, Sensors
119
Protection Device
120
Outdoor Unit
120
BP Unit
121
System Control
122
Outline of System Control
122
Mode Configuration
123
Standby Control at Power on
124
Cooling / Heating Standby Operation at Startup
125
Equalizing Control
126
Determination of Initial Frequency
128
Oil Return Operation
133
Defrost Operation
135
PART 5 3.8 Defrost Operation
135
Pre-Equalization Standby Operation
136
Equalizing Control
137
Capacity Control
139
Peak Cut Control
141
Freeze-Up Prevention
142
Gas Shortage Malfunction
143
Discharge Pipe Control
144
Input Current Control
145
Wet Protection Control I
148
Electric Parts Cooling and Electric Parts / Fin Temperature Control
149
Differential Pressure Control
150
Year-Round Cooling-Only Function
151
Nighttime Low Noise Control
152
PI Control
153
Warm-Up Function
154
Compressor Protection Control
155
Fan Control
156
Motorized Valve Control of Outdoor Unit
158
Cooling Outdoor Unit SC Control
164
BP Unit Motorized Valve Control
165
Gas Pipe Isothermal Control in Cooling Operation
168
SH Control in Cooling Operation
170
SC Control in Heating Operation
172
Heat Exchanger Isothermal Control in Heating Operation
174
BP Unit Motorized Valve Control in High Discharge Pipe Temperature
175
Inter-BP Units Heating Heat Exchanger Isothermal Control
176
Inter-BP Units Gas Pipe Isothermal Control
177
BP Unit Motorized Valve Control by Target Discharge Pipe Temperature
178
4-Way Valve Operation
179
JIS Mode
180
Pump down Operation
181
Protection Control of Skyair Indoor Units
182
Part 6 Flow of Refrigerant
184
Flow of Refrigerant
185
Standby Operation (Cooling)
186
Equalizing Control (Cooling)
187
Oil Return Operation (Cooling)
188
Low Outside Air Temperature Cooling
189
All-Room Operation (Cooling)
190
Multi-Room Operation (no Surplus Refrigerant) (Cooling)
191
Multi-Room Operation (Cooling) (with Surplus Refrigerant)
192
1-Room Operation - Indoor Unit with Large Capacity (Cooling)
193
1-Room Operation - Indoor Unit with Small Capacity (2.5 Kw) (Cooling)
194
Standby Operation (Heating)
195
Equalizing Control (Heating)
196
Oil Return Operation (Heating)
197
1.14 Defrost Operation
198
All-Room Operation (Heating)
199
Multi-Room Operation (with Non-Operating Room Unit) (Heating)
200
Multi-Room Operation (Heating)
201
1-Room Operation - Indoor Unit with Large Capacity (Heating)
202
1-Room Operation - Indoor Unit with Small Capacity (2.5 Kw) (Heating)
203
Part 7 Operations
204
Remote Controller
205
Wireless Remote Controller
205
Si18
214
Wired Remote Controller
215
Part 8 Operating Test
218
Operating Test
219
Test Operation Switch
222
Pump down Operation Switch
223
Record of the Installation Position
224
Method of Field Set
225
Field Setting
225
Initial Setting Contents
226
Detailed Explanation of Setting Modes
228
Group Number Setting for Central Remote Control
233
Interface Adaptor for Room Airconditioner <KRP928A1S
234
Precautions: for RMK140J / RMX140J Outdoor Unit Users
236
Part 9 Service Diagnosis
238
Troubleshooting - Split Type Indoor Unit
239
Troubleshooting with the Operation Lamp
239
Service Check Function
241
Code Indication on the Remote Controller
243
Troubleshooting
244
Troubleshooting Detail
245
Troubleshooting - Skyair Indoor Unit
259
The INSPECTION/TEST Button
259
Self-Diagnosis by Wired Remote Controller
260
Fault Diagnosis by Wireless Remote Controller
261
Troubleshooting by LED on the Indoor Unit's
263
Troubleshooting by Remote Controller Display / LED Display
264
Troubleshooting Detail
265
Indoor Unit Fan Motor Lock
268
Troubleshooting - Outdoor Unit Related
273
The Unit Runs but Doesn't Cool (Heat) the Room
273
Seg. Display on the Outdoor P. C. Board
275
Troubleshooting Detail
276
Compressor Lock
277
Transmission Error between Outdoor Unit and Bp Unit
304
Transmission Error between Indoor Unit and Bp Unit
306
How to Check
313
Service Diagnosis
315
Thermistor Resistance Check
318
Power Supply Waveforms Check
321
BP Unit Trouble Diagnosis
323
PCB Parts Layout
323
LED on Branch Provider Unit (Diagnosis Leds)
323
Part 10 Removal Procedure
324
For BPMK928B42 · 43
325
Installation of Indoor Unit
325
Opening of Electrical Box Cover and Removal of PCB Mount
326
Removal of Motorized Valve
328
Removal of Thermistor
331
Outdoor Unit
333
Removal of Outer Panels
333
Removal of PCB and Electrical Box
334
Removal of Propeller Fans and Fan Motors
342
Removal of Thermistor
344
Removal of Motorized Valve
345
Removal of Sound Insulation
347
Removal of Compressor
349
Removal of 4-Way Valve
351
Indoor Unit
355
Refer Following Table for Indoor Unit Removal Procedure
355
Part 11 Cautions before Operation
356
Installation
357
Outdoor Unit
357
BP Unit
359
Wiring
361
Outdoor Unit
361
BP Unit
363
Outdoor Unit Rotary Switch Setting
365
Others
367
Explanation for FTK(X)25/35J Series
367
Centralized Control
368
Explanation for FTK(X)50/60H and CDK(X)25~60H Series
370
Part 12 Appendix
372
Piping Diagrams
373
Outdoor Units
373
BP Units
375
Indoor Units
376
Wiring Diagrams
383
Outdoor Units
383
BP Units
387
Indoor Units
388
Index
402
Daikin FDYM03FAV1 Operation Manual (14 pages)
Split System Air Conditioner
Brand:
Daikin
| Category:
Air Conditioner
| Size: 1 MB
Table of Contents
Air Conditioner
1
Operation Manual
1
Split System
1
Table of Contents
4
Safety Considerations
4
What to Do before Operation
4
Operation Range
6
Installation Site
7
Name and Function of each Switch and Display on the Remote Controller
7
Operation Procedure
8
Maintenance (for Service Personnel)
10
Optimum Operation
10
Not Malfunction of the Air Conditioner
11
Trouble Shooting
12
Specifications
13
Advertisement
Advertisement
Related Products
Daikin FDYM60FAV1
Daikin FDMQ-R Series
Daikin Super Multi NX FDXS12LVJ
Daikin FDXS-L Series
Daikin FDXV41NVLT
Daikin FDXV50NVLT
Daikin FDXV63NVLT
Daikin FDXV71NVLT
Daikin FDXS25EV2C
Daikin FDXS35EV2C
Daikin Categories
Air Conditioner
Heat Pump
Chiller
Remote Control
Air Handlers
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL