Cdx25~60Hav Series, Cdk25~60Hav Series - Daikin FTX25JVEA9 Service Manual

Super multi plus j series
Hide thumbs Also See for FTX25JVEA9:
Table of Contents

Advertisement

Printed Circuit Board Connector Wiring Diagram and Name
1.5

CDX25~60HAV Series, CDK25~60HAV Series

Cooling Only
CDK25 / 35 / 50 / 60HAVE (A) (C) (T)
Heat Pump
CDX25 / 35 / 50 / 60HAVEA (C), CDX25 / 35 / 50 / 60HAV1NB,
CDX25 / 35 / 50 / 60JV1NB, CDX25 / 35JVEC
Printed Circuit
Printed Circuit Board (1) (Control PCB)
Printed Circuit Board (3) (Intelligent Eye Sensor PCB)
Board
Name of Connector
1) S1
2) S6
3) S7
4) S21
5) S36
6) S26
7) S35
Note:
Other designations
1) V1
2) JA
3) LED1 (GRN) LED for Operation
4) LED2 (YLW) LED for Timer
5) LED3 (GRN) LED for Intelligent Eye
68
Connector for Fan Motor
Connector for Swing Motor (Horizontal Flap)
Connector for Fan Motor
Connector for Centralized Control to 5 Rooms
Connector for Control PCB
Connector for Signal Receiver PCB
Connector for Intelligent Eye Sensor PCB
Varistor
Address Setting Jumper
JB
Fan Speed Setting when Compressor is OFF on Thermostat.
JC
Power Failure Recovery Function.
Printed Circuit Board Connector Wiring Diagram and Name
Si18-201

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents