Equalizing Control - Daikin FTX25JVEA9 Service Manual

Super multi plus j series
Hide thumbs Also See for FTX25JVEA9:
Table of Contents

Advertisement

System control
3.10

Equalizing Control

Outline
This function provides equalizing control after a standby operation in order to prevent the
compressor from
locking due to insufficient equalization and to ensure smooth compressor startup.
Details
Equalizing control in cooling
Equalizing control in cooling
4-way valve
Command
frequency
Outdoor unit
upper fan
Outdoor unit
lower fan
Fan OFF delay
time
EVP
EVL
EVG
Each room
motorized valve
BP bypass
motorized valve
Equalizing
interval timer
124
3 min standby timer 180sec
Standby
operation
OFF
OFF
700rpm
650rpm
150sec
450 pulses
450 pulses
52 pulses
0 pulse
0 pulse
25sec
450 pulses
450 pulses
450 pulses
450 pulses
0 pulse
0 pulse
25sec
80sec
Si18-201
450 pulses
100 pulses
0 pulse
(M1014)