2. Protection Device

2.1

Outdoor Unit

M1C
Compressor
J1HC
Crankcase Heater
HPS
High Pressure Protection
SP
Low Pressure Sensor
Y1E
Electronic
(EV
)
Expansion Valve
G
Y2E
Electronic
(EV
)
Expansion Valve
L
Y3E
Electronic
(EV
)
Expansion Valve
P
Y1R
4-Way Valve
M1F
Fan Motor (Lower)
M2F
Fan Motor (Upper)
C1R
Capacitor for Fan Motor
L1R
Direct Current Reactor
L2R
Direct Current Reactor
F1U
FUSE
R1T
Thermistor (Condenser)
R2T
Thermistor (Liquid)
R3T
Thermistor (Outdoor)
R4T
Thermistor (Suction)
R5T
Thermistor (Discharge)
Main Functions
JT100F-VD
(3SA45022-1)
OFF: 2.94MPa ON: 2.16MPa
(3SA48112-1) PS8040A
0~0.98MPa
Main Body (2SB45422-1)
Coil (3SB45348-8)
Main Body (2SB45422-1)
Coil (3SB45348-1)
Main Body (3SA52028-1)
Coil (3P002169-1)
Main Body (3SA52023-1)
V40100B
Coil (3SA52037-5-KU)
(3SB40509-1) H41, L30-W × 1 8P Propeller
(3SB40509-1) H53, L38-W × 1 8P Propeller
(3EB60099-1) 2,500µF
(3EB75084-1)
(3EB75084-1)
(3EB82010-1) (250)V (3.15)A
(3EB70006-19) R25 = 20kΩ B = 3,950
(3EB70006-29) R25 = 20kΩ B = 3,950
(3EB70001-9) R25 = 20kΩ B = 3,950
(3EB70006-19) R25 = 20kΩ B = 3,950
(3EB70006-19) R25 = 20kΩ B = 3,950

Protection Device

RMX140JVM
3.3kW × 1 Scroll
LAM-B30YHDM-1
LAM-B30YHDM-1
EKV-30D36
V40100B H/p Only
107