Outdoor Unit Rotary Switch Setting - Daikin FTX25JVEA9 Service Manual

Super multi plus j series
Hide thumbs Also See for FTX25JVEA9:
Table of Contents

Advertisement

Wiring
2.3

Outdoor Unit Rotary Switch Setting

Setting Position
* RAM View Monitor
RSW1
RSW2
Remarks
0
0
Latest (status) error code
0
1
Latest (status) error spot
0
2
Current run mode
0
3
Current 4-way valve
0
4
Current operating frequency (Hz)
0
5
Current EVP
0
6
Current EVG
0
7
Current EVL
0
8
Current fan (upper)
0
9
Current fan (lower)
1
0
Current input current
1
1
Current total input current
1
2
Current high pressure (calculated)
1
3
Current suction pressure
1
4
Current outdoor temperature
1
5
Current discharge temperature
1
6
Current suction temperature
1
7
Current outdoor heat exchange temperature
1
8
Current outdoor fluid pipe temperature
1
9
Current fin temperature
2
0
Current box temperature
2
1
Current BP 1 Room-A motorized valve openness
2
2
Current BP 1 Room-B motorized valve openness
2
3
Current BP 1 Room-C motorized valve openness
2
4
Current BP 2 Room-A motorized valve openness
2
5
Current BP 2 Room-B motorized valve openness
2
6
Current BP 2 Room-C motorized valve openness
2
7
Current BP 3 Room-A motorized valve openness
2
8
Current BP 3 Room-B motorized valve openness
2
9
Current BP 3 Room-C motorized valve openness
3
0
3
1
Current BP 1 Room-A fluid pipe temperature
3
2
Current BP 1 Room-B fluid pipe temperature
3
3
Current BP 1 Room-C fluid pipe temperature
3
4
Current BP 2 Room-A fluid pipe temperature
3
5
Current BP 2 Room-B fluid pipe temperature
3
6
Current BP 2 Room-C fluid pipe temperature
3
7
Current BP 3 Room-A fluid pipe temperature
3
8
Current BP 3 Room-B fluid pipe temperature
3
9
Current BP 3 Room-C fluid pipe temperature
352
SW1, SW2
Switch Bo
SW1
SW2
Service Monitor
x
7 seg. display
(Q0008)
Unit
Error code
Standard
Status
Status
Frequency
EV openness
EV openness
EV openness
Fan rpm
Fan rpm
Ampere
Ampere
Pressure
Pressure
Temp. offset 40h
Temperature
Temp. offset 40h
Temp. offset 40h
Temp. offset 40h
Temperature
Temp. offset 40h
EV openness
EV openness
EV openness
EV openness
EV openness
EV openness
EV openness
EV openness
EV openness
Temp. offset 40h
Temp. offset 40h
Temp. offset 40h
Temp. offset 40h
Temp. offset 40h
Temp. offset 40h
Temp. offset 40h
Temp. offset 40h