Si18-201
1.8

FDYM60FA, FDYM03FA Series

Cooling Only /
FDYM60FAV1, FDYM60FAV1C, FDYM60FAVAL
FDYM03FAV1, FDYM03FAV1C, FDYM03FAVAL
Heat Pump
Name of Connector
1) X5A
2) X10A
3) X11A
4) X15A
5) X18A
6) X19A
7) X21A
8) X27A
9) X30A
10) X33A
11) X35A
Other Designation
1) H1P,H2P
Printed Circuit Board Connector Wiring Diagram and Name
Printed Circuit Board Connector Wiring Diagram and Name
Connector for Wired Remote Controller
Connector for Transformer
Connector for Transformer
Jumpered
Connector for Thermistor (Coil)
Connector for Thermistor (Air)
Connector for Fan Motor
Connector for Outdoor Unit
Connector for Interface Adaptor (Option)
Connector for Adaptor for Wiring (Option)
Connector for Group Control Adaptor (Option)
Service Monitor LED (Green)