Powerful Operation - Daikin FTX25JVEA9 Service Manual

Super multi plus j series
Hide thumbs Also See for FTX25JVEA9:
Table of Contents

Advertisement

Main Functions
1.1.31
Emergency Operation Function (ON/OFF
The unit can be turned ON only by pressing ON/OFF operation switch. This is convenient when
the remote controller cannot be found or if the batteries are dead.
The operation condition is as follows:
Operation mode
Fan speed
Set temperature
Pressing the switch again will turn the unit OFF.
1.1.32

Powerful Operation

During cool and program dry operation, when the POWERFUL button on the remote controller
is pressed, the thermistor setting is changed to the lowest setting of the remote controller and
the fan runs at the maximum rpm (Note). During fan operation, air is blown at the maximum fan
rpm.
Note:
Max. fan rpm = H tap set by remote controller + 50 rpm
Notes on POWERFUL Operation
"
"
96
In COOL mode
To maximize the cooling effect, the temperature setting is fixed to 18°C and the air flow rate
is fixed to the maximum setting. (H tap + 50 r.p.m)
The temperature and air flow settings are not variable.
In DRY mode
The temperature setting is lowered by 3°C and the air flow rate is slightly increased. You can
repeat POWERFUL operation if you need even more dehumidification.
Switch)
Cool
Auto
22°C
Si18-201