Removal Of Motorized Valve - Daikin FTX25JVEA9 Service Manual

Super multi plus j series
Hide thumbs Also See for FTX25JVEA9:
Table of Contents

Advertisement

Si18-201
1.3

Removal of Motorized Valve

Procedure
Step
1. Detaching the bottom
panel
1
Loosen the two
keyhole-provided
screws and remove the
two other screws from
the electrical mounting
plate.
2. Removing the motorized
valve coil
Slide the motorized
1
valve coil to the right
and take it out.
3. Undoing the clamp
1
Remove the harness
clamp from the side.
Removal Procedure
Warning
Be sure to turn off all power supplies before disassembling work.
Procedure
For BPMK928B42 · 43
Points
"
When reassembling, make
sure the motorized valve coil
spring clicks and feels
caught.
"
The plain, red, blue and
yellow markings are
provided from the front
bottom.
315