Daikin FD(Y)M03FAV1(C) Operation Manual

Split system air conditioner
Hide thumbs Also See for FD(Y)M03FAV1(C):

Advertisement

SPLIT SYSTEM

MODELS
(Duct connection type)
FD(Y)M03FAV1(C)
FD(Y)M04FAV1
FD(Y)M05FAV1
FDYM06FAV1
FDYM60FAV1(C)

OPERATION MANUAL

FD(Y)M03FAVAL
FD(Y)M04FAVAL
FD(Y)M05FAVAL
FDYM06FAVAL
FDYM60FAVAL

Air Conditioner

English
Español

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FD(Y)M03FAV1(C)

  • Page 1: Operation Manual

    OPERATION MANUAL English SPLIT SYSTEM Air Conditioner Español MODELS (Duct connection type) FD(Y)M03FAV1(C) FD(Y)M03FAVAL FD(Y)M04FAV1 FD(Y)M04FAVAL FD(Y)M05FAV1 FD(Y)M05FAVAL FDYM06FAV1 FDYM06FAVAL FDYM60FAV1(C) FDYM60FAVAL...
  • Page 2 Thank you for purchasing this Daikin air condi- tioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, file it away for future reference.
  • Page 3 • •...
  • Page 4: Table Of Contents

    SWITCH AND DISPLAY ON THE REMOTE CONTROLLER ......4 NOTE 6. OPERATION PROCEDURE ......5 • Contact your Daikin dealer in case of changing 7. OPTIMUM OPERATION ........ 7 the combination or setting of group control and 8. MAINTENANCE two remote controller control systems.
  • Page 5 Ask your dealer to move and reinstall the air CAUTION ..These are the matters with possi- conditioner. bilities leading to injury or material Incomplete installation may result in a water damage due to erroneous han- leakage, electric shock, and fire. dling including probabilities lead- Do not use any fuse with improper capacity.
  • Page 6: Operation Range

    Never expose little children, plants or ani- 3. OPERATION RANGE mals directly to the air flow. If the temperature or the humidity is beyond the fol- Adverse influence to little children, animals and plants may result. lowing conditions, safety devices may work and the Do not wash the air conditioner with water.
  • Page 7: Installation Site

    HEATING • Make sure that a separate power supply cir- cuit is provided for this air conditioner and TEMPERATURE(°C) OUTDOOR that all electrical work is carried out by quali- UNIT OUTDOOR INDOOR fied personnel according to local laws and regulations. –9 to 21 RY-FUV1/Y1 15 to 27...
  • Page 8: Operation Procedure

    • Operating procedure varies with heat pump type DISPLAY “ ” (FAN SPEED) and cooling only type. Contact your Daikin dealer This display shows the set fan speed. to confirm your system type. • To protect the unit, turn on the main power switch DISPLAY “...
  • Page 9 • Micro computer automatically determines Each time this button is pressed, setting TEMPERATURE and FAN SPEED. temperature rises 1°C. • This system does not go into operation if the Each time this button is pressed, setting room temperature is below 16°C. temperature lowers 1°C.
  • Page 10: Optimum Operation

    • Adjust the room temperature properly for a comfort- cially available. able environment. Avoid excessive heating or cooling. • Ask your DAIKIN dealer how to clean them. • Prevent direct sunlight from entering a room dur- ing cooling operation by using curtains or blinds.
  • Page 11: Not Malfunction Of The Air Conditioner

    It is necessary to clean the • Refer to “FAN OPERATION”. inside of the indoor unit. Ask your Daikin dealer for details on cleaning the unit. This operation Cut off the power supply. requires a qualified service person.
  • Page 12: Trouble Shooting

    MALFUNCTION CODE • If direct sunlight enters the room (when cool- ing). Measure: Notify your Daikin dealer and inform Use curtains or blinds. him/her of the display. • When there are too many inhabitants in the room (when cooling).
  • Page 13: Specifications

    11.SPECIFICATIONS (These specifications are in compliance with SASO386.) English...