Sign In
Upload
Manuals
Brands
Beckman Coulter Manuals
Laboratory Equipment
Optima L-XP
Beckman Coulter Optima L-XP Manuals
Manuals and User Guides for Beckman Coulter Optima L-XP. We have
2
Beckman Coulter Optima L-XP manuals available for free PDF download: Instructions For Use Manual
Beckman Coulter Optima L-XP Instructions For Use Manual (110 pages)
Preparative Ultracentrifuges L-XP Series
Brand:
Beckman Coulter
| Category:
Laboratory Equipment
| Size: 2.06 MB
Table of Contents
Table of Contents
7
Certification
15
Introduction
15
Safety Notice
15
Scope of Manual
15
CFC-Free Centrifugation
16
Recycling Label
16
Rohs Notice
16
Software Copyright
17
CHAPTER 1 Description
19
Instrument Function
19
Introduction
19
Safety Features
20
Door
20
Barrier Ring
20
Imbalance Detector
20
Overspeed System
20
Dynamic Rotor Inertia Check (DRIC)
21
Instrument Chassis
21
Rotor Chamber
21
Vacuum System
21
Drive
21
Temperature Sensing and Control
22
Controls and Indicators
22
Power
22
Key Switch Positions
23
Control Panel
23
Name Rating Plate
22
Optima L-XP Control Head
23
Control Panel
24
Settings Screen
24
Step Program Screen
25
Specifications
27
Available Rotors
28
CHAPTER 2: Operation
29
Introduction
29
Power
29
Key Switch Positions
29
Normal Position
30
Locked Position
30
Zonal Position
30
Touchscreen Interface
30
Basic Operation
31
Touchscreen and Keypad Operation
31
Logging in
32
System-Level Operations
33
User Login Screen
33
Adding a User
34
System Management Screen
34
Add User Screen
34
New PIN Screen
35
Confirm PIN Screen
35
Copying Users
36
Set Role Screen
36
Set PIN Number
37
Set Role
38
Removing Users
38
Require User Login
39
Required Rotor Selection
39
Enable User Login Option
39
Enable Run Comment
40
Manual Operation
40
Settings Screen
40
Delay Start Screen
42
Programmed Operation
43
Precool/Heat Temperature Screen
43
Setup Menu
44
File Types
44
Step Program
45
Step Program Screen
45
Save as Dialog
46
RPM to RCF Toggle
47
RCF Conversion
47
RCF Run Screen
47
W2T
49
Rotor Conversion
50
Substitute Rotor Screen
50
Auto Pelleting
51
Auto Rate Zonal
52
Auto Pelleting Run Screen
52
Auto Rate Zonal Screen
53
Recall Program
54
Remote Operation
54
Open File Dialog
54
Using Calculation Features
55
Pelleting Time Calculation
55
Calculate Menu
55
Calculate Pelleting Time Screen
55
Concentration Measures
56
Calculate Concentration Measures Screen
56
Refractive Index/Density
57
Speed Reduction for Dense Solutions
57
Calculate Refractive Index/Density Screen
57
Speed Reduction for Precipitating Solutions
58
Calculate Reduced Rotor Speed for Dense Solutions Screen
58
Sedimentation Coefficient from Run Data
59
Calculate Reduced Rotor Speed for Precipitating Solutions Screen
59
Sedimentation Coefficient from Molecular Mass
60
Calculate Sedimentation Coefficient from Run Data Screen
60
Restore Windows
61
Estimate Sedimentation Coefficient from Molecular Mass Screen
61
CHAPTER 3 Simulations
63
Using Simulation Features
63
ESP Pelleting
63
Simulate Menu
63
ESP Pelleting Screen
64
ESP Rate Zonal
65
ESP Rate Zonal Screen
65
ESP Plasmid Run
66
ESP Plasmid Run Screen
67
Esp Rna (Best)
68
ESP RNA (Fast)
69
ESP RNA (Fast)
70
Recall Simulation
71
CHAPTER 4 Reference and Log Functions
73
Reference Features
73
Rotor Catalog
73
Reference Menu
73
Rotor Catalog Screen
74
Rotor Library
75
Selected Rotor Specifications
75
Select Rotor Screen
75
Enter Rotor Serial Number Screen
76
Tube Catalog
77
Chemical Resistances
78
Selected Tube Specifications
78
Chemicals/Upac Name Screen
79
Exporting Data
80
Chemical Resistances Screen
80
Optima L-XP Control Head with USB Hub
81
Export Data Screen
81
Log Features
82
Instrument Usage Log
82
Display Last Run Record
82
Logs Menu
82
Run Record
83
Preinstallation Requirements
83
CHAPTER 5 Troubleshooting
85
Introduction
85
User Messages
85
Retrieving Your Sample in Case of Power Failure
87
Removing the Control Head Cover
88
Depressing the Latch to Loosen the Front Panel
89
Interior View of Instrument (Panel Removed)
89
Reinstalling the Front Panel
90
CHAPTER 6 Care and Maintenance
91
Introduction
91
Cleaning
91
Rotor Chamber
91
Decontamination
92
Sterilization and Disinfection
92
Storage and Transportation
92
Supply List
93
Replacement Parts
93
Supplies
93
APPENDIX A: Preinstallation Requirements
95
Introduction
95
Space Requirements
95
Bio-Safety Level 3 Installation
96
Electrical Requirements
96
Dimensions of the Optima L-XP Ultracentrifuge
96
Attaching a Printer
97
Electrical Connection
97
Printer Connection
98
APPENDIX B: Remote Access
99
Introduction
99
VNC License Information
100
About Optima L-XP Screen
100
GNU General Public License, Version 2, June 1991
101
Preamble
101
GNU General Public License Terms and Conditions for Copying, Distribution and Modification
102
Beckman Coulter, Inc
107
Optima L, LE, L-XP, and XL
107
Preparative Ultracentrifuges Warranty
107
Related Documents
110
Advertisement
Beckman Coulter Optima L-XP Instructions For Use Manual (56 pages)
Preparative Ultracentrifuges
Brand:
Beckman Coulter
| Category:
Laboratory Equipment
| Size: 1.39 MB
Table of Contents
Alerts for Warning, Caution, and Note
3
Safety During Installation And/Or Maintenance
3
Safety Notice
3
Chemical and Biological Safety
4
Electrical Safety
4
Safety against Risk of Fire
4
Table of Contents
7
Instrument Certification
13
Introduction
13
Scope of Manual
13
Conventions
14
Recycling Label
14
Rohs Notice
15
Specifications
16
Preinstallation Requirements
18
CHAPTER 1 Description
21
Introduction
21
Key Switch Positions
21
Power
21
Standby Mode
21
Control Panel
22
Keys
22
Displays
22
Run Status Indicators
23
Diagnostic Messages
24
Door
24
Rotor Chamber
24
Vacuum System
24
Temperature Control System
25
Temperature Sensing
25
Drive
26
Name Rating Plate
26
Overspeed
26
Rotor Energy System
26
CHAPTER 2: Run Preparation
27
Introduction
27
Power
27
Key Switch Positions
27
Standard Operation
28
Keypad
28
Parameter Keys
29
Programmed Operation
33
Activation Keys
34
Delayed Start Program Function
36
Entering Program
36
Running Program 0 with a Second Program
37
Editing Settings During the Delayed Start Run
37
CHAPTER 3: Run Procedure
39
Introduction
39
Standard Operation
39
Repeating a Run
40
Programmed Operation
40
Delayed Start Program Function
41
Zonal Operation
42
Acceleration
43
Deceleration
43
Unloading
43
Points to Remember
44
CHAPTER 4: Troubleshooting and Maintenance
45
Introduction
45
In Case of Power Failure During Run
45
Retrieving Your Sample
45
Diagnostic Messages
49
Cleaning
51
Decontamination
51
Sterilization and Disinfection
51
Storage and Transportation
52
Supply List
52
Beckman Coulter, Inc
53
Optima L, LE, L-XP, and XL Preparative Ultracentrifuges
53
Advertisement
Related Products
Beckman Coulter Optima XPN
Beckman Coulter Optima XE Series
Beckman Coulter Optima MAX-XP
Beckman Coulter Optima TLX
Beckman Coulter Optima L Series
Beckman Coulter Optima LE
Beckman Coulter Optima XL
Beckman Coulter Optima XL Series
Beckman Coulter MET ONE 3411
Beckman Coulter MET ONE 3415
Beckman Coulter Categories
Laboratory Equipment
Measuring Instruments
Medical Equipment
Desktop
Cash Counter
More Beckman Coulter Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL