Individual settings
Checking the machine zero point
1. In the Extras > Service > Multitest menu, enter the password
2. Tap on the Transport clamp menu.
3. Tap the
 The machine moves to the reference positon.
4. Tap on Test button.
 The machine moves to the test position.
Correct setting
The center of the needle is positioned above the hole (1) and the tip of the
needle can be lowered into the hole by pressing and turning the arm shaft
crank.
Important
Contact Customer Service if the setting is incorrect,  3.18 Customer
Service, page 81.
5. Move the machine to the reference positon.
6. Tap the
7. Tap the
 The reference run is requested.
8. Press both start buttons.
 The machine performs a reference run.
9. Remove the gage, install the configuration set and set it if necessary,
Service manual 906 - 00.0 - 11/2014
NOTE
Damage to the gage and the sewing foot if the machine moves to
another position!
Do not press the start buttons during the test.
(25483).
button.
button to switch to the Multitest menu.
button to exit the Multitest menu.
 4.6 Setting the material feeder linear drive, page 100.