Individual settings
Figure 19: Setting the needle guide
①
②
(1) - Throat plate
(2) - Screws
(3) - Needle guide
Setting steps
1. Loosen the screws (2).
2. Remove the throat plate (1).
3. Rotate the machine to position 1 ( page 18).
4. Loosen the screw (4).
5. Move the needle guide (3) as close as possible against the needle.
6. Tighten the screw (4).
7. Check this distance using a piece of paper (5).
Service manual 906 - 00.0 - 11/2014
(4) - Screw
(5) - Paper
⑤
④
③
31