Set Mode; Set Mode Programming; Set Mode Items - Icom IC-M603 Instruction Manual

Marine
Hide thumbs Also See for IC-M603:
Table of Contents

Advertisement

■ Set mode programming

Set mode is used to change the conditions of the trans-
ceiver's functions: Scan type*
tone, Internal speaker, LCD contrast, Automatic foghorn fre-
quency, Radio power*
2
, Scrambler type*
and Favorite channel.
*
1
Except for Holland version.
*
2
Appears only when an optional COMMANDMICIII™ is connected.
*
3
Appears only when an optional scrambler unit is installed.
Available functions may differ depending on dealer setting.
q While pushing and holding [16•C], push [POWER] to
enter Set mode.
• Turn power OFF in advance.
w After the display appears, release [16•C].
e Rotate [SELECTOR] to select the desired item, push [ENT].
r Rotate [SELECTOR] to select the desired condition of the
item, push [ENT] to set.
t Push [CLR], or rotate [SELECTOR] to select "Exit" then
push [ENT] to exit Set mode and returns to normal condition.
• SET MODE CONSTRUCTION
Rotate
1
1
, Scan resume timer*
, Beep
3
, Scrambler code*

--Set Mode--

˘Scan Type
Scan Timer
Beep
Internal Speaker
Contrast
Foghorn Frequency
Radio Power
Scrambler Type
Scrambler Code
Favorite CH
Exit

■ Set mode items

D Scan type
(Except for Holland version)
The transceiver has 2 scan types: normal scan and priority
scan. Normal scan searches all TAG channels in the se-
3
lected channel group. Priority scan searches all TAG chan-
nels in sequence while monitoring Channel 16.
--Set Mode--
Scan Type
Priority
˘Normal
D Scan resume timer
The scan resume timer can be selected as a pause (OFF)
or timer scan (ON). When OFF is selected, the scan pauses
until the signal disappears. When ON is selected, the scan
pauses 5 sec. and resumes even if a signal has been re-
ceived on any other channel than Channel 16.
--Set Mode--
Scan Timer
ON
˘OFF
SET MODE
(Default: Normal)
(Except for Holland version)
(Default: OFF)
8
7
8
43

Advertisement

Table of Contents
loading

Table of Contents