Conventional Battery Testing

Whenever a service complaint is related to either the starting or
charging systems, the battery should be checked first.
Following are three tests which can easily be made on a battery
to determine its condition: OCV Test, Specific Gravity Test and
Load Test.
Conventional Battery OCV - Open Circuit
Voltage Test
Battery voltage should be checked with a digital multitester.
Readings of 12.6 volts or less require further battery testing and
charging. See charts and Load Test below.
NOTE: Lead-acid batteries should be kept at or near
a full charge as possible. Electrolyte level should be
kept between the low and full marks. If the battery is
stored or used in a partially charged condition, or
with low electrolyte levels, hard crystal sulfation will
form on the plates, reducing the efficiency and
service life of the battery.

Conventional Battery Specific Gravity Test

A tool such as a Battery Hydrometer (PN 2870836) can be used
to measure electrolyte strength or specific gravity. As the
battery goes through the charge/discharge cycle, the electrolyte
goes from a heavy (more acidic) state at full charge to a light
(more water) state when discharged. The hydrometer can
measure state of charge and differences between cells in a multi-
cell battery. Readings of 1.270 or greater should be observed in
a fully charged battery. Differences of more than .025 between
the lowest and highest cell readings indicate a need to replace
the battery.
10.48
Battery Hydrometer (PN 2870836)
OPEN CIRCUIT VOLTAGE
S
C
TATE OF
ONVENTIONAL
C
L
HARGE
EAD
100%
12.60V
Charged
12.40V
75% Charged
12.10V
50% Charged
11.90V
25% Charged
less than 11.80V
0% Charged
SPECIFIC GRAVITY
S
C
TATE OF
ONVENTIONAL
C
*
L
HARGE
EAD
100%
Charged
75% Charged
50% Charged
25% Charged
less than 1.100
0% Charged
°
* Measurement at 80
F
NOTE: Subtract .01 from the specific gravity reading
°
at 40
F
L
M
OW
AINTENANCE
- A
CID
12.70V
12.50V
12.20V
12.0V
Less than 11.90V
--
--
L
M
OW
AINTENANCE
- A
CID
1.265
1.275
1.210
1.225
1.160
1.175
1.120
1.135
Less than 1.115
--
--