14.2.2. Source Subsystem
This subsystem programs all the output parameters of the RP Series AC source.
Subsystem Syntax
[SOURce:]
CURRent:
VOLTage:
FREQuency:
CURRent
This command sets the rms current limit of the output. If the output current exceeds this limit,
the output latches into a disabled state when current limiting occurs. The output voltage
programming is reset to zero when this condition occurs and the output relay state is set to
OFF.
Note that the CURRent command is coupled with the VRANGe. This means that the
maximum current limit that can be programmed at a given time depends on the voltage
range setting in which the unit is presently operating.
Command Syntax
Parameters
Unit
*RST
Examples
Query Syntax
Returned Parameters
Related Commands
FREQuency
This command sets the frequency of the output sinewave.
Command Syntax
Parameters
Unit
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
RP Series
[LEVel]
RANGe:
[SOURce:]CURRent <NRf>
0 to a value specified by the LIM:CURR
A (rms amperes)
Defined by the PON
CURR 5
CURRent?
<NR2>
VOLT:RANG
[SOURce:]FREQuency <NRf+>
range specified by the LIM:FREQ:LOW and LIM:FREQ:HIGH
commands
Hz (Hertz)
defined by PON
FREQ 50
FREQuency?
<NR2>
LIM:FREQ;LOW?
March 2011
Set the rms current limit in amps.
Set the rms output voltage value in volts.
Set the output voltage range.
Set the output frequency value in Hz.
LIM:FREQ:HIGH?
55