2.1.5.
Unit protection
Input Overcurrent:
Input Overvoltage
Transients:
Output Overcurrent:
Output Overvoltage:
Output Short Circuit:
Overtemperature:
2.2.

Mechanical

Dimensions:
Unit Weight:
Material:
Finish:
Cooling:
Internal Construction: Modular sub assemblies.
Chassis Slides:
Front Panel Mounted
Output Connections:
Rear Panel Mounted
Connections:
RP Series
Electronic current limit with fuse.
Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels.
Shutdown, 0.1 second after overcurrent.
Shutdown, recycle input power to reset.
Peak current limit. Shutdown after 0.1 seconds.
Automatic shutdown.
16.51"(419.4mm) width x 3.5"(88.9 mm) height x 22"(558.8mm)
depth chassis size stand-alone configuration.
37 lbs.
Aluminum chassis, panels and cover.
Yellow iridite then painted semi-gloss polyurethane
Fan cooled with air intake on the sides and exhaust to the rear.
General Devices C300S-118-B308 (use hardware provided to
prevent damage to unit)
CEE 7/7
European socket
US domestic
Single 5-15R 120V line socket
RS232C
Interface
IEEE-488
Interface
Output
Line Input
March 2011
DB 9
D-shell 24 pin
Phoenix Contact HDFK4
IEC 320
5