4.1.3.
The Shuttle Knobs
There are two shuttle knobs located below the LED seven segment displays, which are used
to change setup parameters for voltage, frequency and current limit. The mode button
selects the function of the right shuttle. The right shuttle will control either the frequency or
the current limit as indicated by the indicator above the right LED segment display.
4.1.4.
FUNCTION Buttons
There are three function buttons for the Output Voltage Range, Output State and Shuttle
Mode. The following is a description of these buttons:
KEY
RANGE
OUTPUT
MODE
14
Counter
clockwise
DECREASE

Figure 4-2: Shuttle Knob

DESCRIPTION
The RANGE button is used to change the voltage range
between the low range (0 to 135 volts) and high range (0 to
270 volts). The LED above the switch will light to indicate
the high voltage range selection. The output voltage will be
reset to zero voltage after a range change.
The OUTPUT button will toggle the output to enable or
disable the output. The LED above the button will light when
the output is on. No output voltage will be present when the
OUTPUT button is off despite the level of voltage
programmed.
The MODE button selects the function of the right shuttle
knob and the right LED segment display. The shuttle will
control the output frequency and the display will show the
program frequency value when the mode selection is
frequency. The Shuttle knob will program the current limit
and the display will show its value in the current mode. The
display will revert back to showing the measured current
after 3 seconds from the last movement of the shuttle. The
measurement is updated 4 times per second. The display
mode is indicated by the two LED‟s above the LED segment
display.