User and Programming Manual - Rev R
Appendix C: Error Messages
Error Number
0
-100
-200
-300
-350
-400
76
Table 16: Error Messages
Error Message String
"No error"
"Command error"
"Execution error"
"Device specific error"
"Queue overflow"
"Query error"
March 2011
California Instruments
Error Causes
Generally the result of sending a
command that uses incorrect
syntax.
Generally the result of sending a
value that is out of range, i.e., a
VOLT 200 command when the
unit is in the 136V (Low) range.
Generally the result of an
overcurrent (current limit trip) or
over temperature condition.
Generally caused by too many
errors being generated without
reading error status, causing
error buffer to overflow.
Generally caused by sending a
query followed by another
command without accepting the
query response first.
RP Series