Rpm Limiter; Electronic Power Steering (Eps) - Arctic Cat PROWLER HDX 2015 Service Manual

Table of Contents

Advertisement

RPM Limiter

Component data can be retrieved using the CATT II. Uti-
lize the Sensor Data screen.
NOTE: The ROV is equipped with an ECM that cuts fuel spray and spark when maximum RPM is approached.
When the RPM limiter is activated, it could be misinterpreted as a high-speed misfire.
Gear
2WD
4WD
4WD Lock
2WD Override
4WD Override
Differential-Lock Override
Electronic Power
Steering (EPS)
Component data and system updates can be retrieved/
performed using the CATT II. Navigate the screens as
required.
Certain models were produced with electronic power steer-
ing. The EPS system is an electro-mechanical device that
utilizes 12 volt DC power to drive a motor linked to the
steering shaft to assist the driver when rotating the steering
wheel. Driver steering inputs are detected by a torque-sens-
ing transducer assembly within the EPS housing. These
inputs are converted to electronic signals by the transducer
and control circuitry to tell the motor which way to drive the
steering shaft. When no steering input (pressure on the
steering wheel) is detected, no torque signal is generated,
and no steering assist is provided by the motor.
Code
Fault Description
C1301 Over Current
EPS internal over-current condition
has been detected
C1302 Excessive Current Error EPS internal current measurement
error has been detected
C1303 Torque Sensor Range
EPS internal torque sensor range con-
Fault
dition has been detected
C1304 Torque Sensor Linearity
EPS internal torque sensor linearity
Fault
condition has been detected
C1305 Rotor Position Encoder EPS internal rotor position encoder
condition has been detected
C1306 System Voltage Low
EPS battery power low-voltage condi-
tion has been detected
C1307 System Voltage High
EPS battery power over-voltage condi-
tion has been detected
C1308 Temperature Above
EPS internal 110o C over-temp condi-
110° C
tion has been detected
C1309 Temperature Above
EPS internal 120o C over-temp condi-
120° C
tion has been detected
134
Park
Neutral
Reverse
4000
2250
6500
4500 (500)
5000 (700)
7000
Fault Condition
High/Low
Fail-Safe Mode
7650 (500)
4000
7250 (700)
The EPS system is battery-system powered; therefore, the
battery must be in good condition and fully charged.
Power delivery and overload protection are provided by an
EPS relay and 30-amp fuse, located under the seat in the
Power Distribution Module (PDM).
If a system malfunction occurs, a diagnostic trouble code
(DTC) will be displayed on the LCD gauge. Initially, the
gauge will go blank for 30 seconds and the code will flash;
then the gauge will return to normal except the code will
continue to be displayed.
Possible Cause
Internal EPS Condition
Internal EPS Condition
Internal EPS Condition
Internal EPS Condition
Internal EPS Condition
System voltage low (less than 11 VDC at the
EPS). Wire harness issue, faulty voltage regu-
lator, weak battery or loose battery terminals.
System voltage high (more than 16 VDC at
the EPS). Wire harness issue, faulty voltage
regulator or loose battery terminals.
Clean the EPS housing and cooling fins.
Clean the EPS housing and cooling fins.
Warranty
Incorrect ECU/
Registration
Gauge (P0630)
(U1001)
6650
4500
EPS Fault Recovery Method
Correct EPS condition*
Correct EPS condition*
Correct EPS condition*
Correct EPS condition*
Correct EPS condition*
EPS will auto-recover when the bat-
tery supply returns to normal
EPS will auto-recover when the bat-
tery supply returns to normal
EPS will auto-recover when internal
temperature drops below 105° C
EPS will auto-recover when internal
temperature drops below 115° C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents