Serveraid Error Codes - IBM Eserver xSeries 335 Type 8676 Hardware Maintenance Manual And Troubleshooting Manual

Hide thumbs Also See for Eserver xSeries 335 Type 8676:
Table of Contents

Advertisement

ServeRAID error codes

In the following error codes, x can be any number or letter.
Note: See "System" on page 116 to determine which components should be replaced by a field service technician.
Error code/symptom
1xxx (Microcode checksum error)
2xxx (Code DRAM error)
3000-31XX (Code DRAM error)
3200 (Code DRAM error)
3300 (ServeRAID-5i only)
3E20 (ServeRAID-5i only)
3E2x
4xxx thru 5xxx (Code DRAM error)
6xxx (Cache DRAM error) (ServeRAID-4H only)
7xxx thru 8xxx (Host/local PCI bus interface error)
FRU/action
1. ServeRAID controller
1. Install download jumpers, flash latest level BIOS and
firmware for controller. Remove jumpers.
2. ServeRAID controller.
1. Install download jumpers, flash latest level BIOS and
firmware for controller. Remove jumpers.
2. ServeRAID controller.
1. Install download jumpers, flash latest level BIOS code
and firmware for controller. Remove jumpers.
2. ServeRAID controller.
1. Install ServeRAID-5i controller in an extended PCI
expansion slot. See the documentation that came with
the server for more information.
1. Remove the ServeRAID-5i controller from its slot and
install it in the proper PCI option slot.
2. Verify that the ServeRAID-5i controller is supported in
this server.
3. ServeRAID-5i controller.
4. System board.
1. Reseat the ServeRAID controller.
2. Flash latest level of BIOS code and firmware for
controller.
3. ServeRAID-5i controller.
4. Integrated RAID controller on server).
1. Install download jumpers, flash latest level BIOS code
and firmware for controller; then, remove jumpers.
2. ServeRAID controller.
1. Reseat daughter card.
2. Install download jumpers, flash latest level BIOS code
and firmware for controller; then, remove jumpers.
3. ServeRAID controller.
1. Flash latest level of BIOS code and firmware for
controller.
2. If ServeRAID-4x controller, replace controller.
3. If ServeRAID-5i controller, integrated RAID controller
on the server.
Chapter 6. Symptom-to-FRU index
105

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver xseries 335 type 8830

Table of Contents