Note: See "System" on page 116 to determine which components should be replaced by a field service technician.
Error code/symptom
020-XXX-003 (Failed hot-swap slot 3 PCI
latch test)
020-XXX-004 (Failed hot-swap slot 4 PCI
latch test)
030-XXX-000 (Failed internal SCSI
interface test)
035-XXX-099
035-XXX-s99 (Failed RAID test on PCI slot
s. s = number of failing PCI slot. Check
System Error Log before replacing a FRU.)
035-XXX-snn (Check System Error Log
before replacing a FRU. s = number of
failing PCI slot, nn = SCSI ID of failing fixed
disk.)
035-253-s99 (RAID adapter initialization
failure)
075-XXX-000 (Failed power supply test)
089-XXX-001 (Failed microprocessor test)
089-XXX-002 (Failed optional
microprocessor test)
165-060-000 (Service Processor: ASM may
be busy)
165-198-000 (Service Processor: Aborted)
165-201-000 (Service Processor: Failed)
165-330-000 (Service Processor: Failed)
FRU/action
1. PCI hot-swap latch assembly
2. System board
1. PCI hot-swap latch assembly
2. System board
v System board
1. No adapters were found.
2. If adapter is installed re-check connection.
1. RAID adapter
2. SCSI backplane
3. Cable
v Hard disk drive with SCSI ID nn on RAID adapter in PCI slot s.
1. ServeRAID adapter in slot s is not configured properly. Obtain
the basic and extended configuration status and see the ServeRAID
Hardware Maintenance Manual for more information.
2. Cable.
3. SCSI backplane.
4. Adapter.
v Power supply
1. Microprocessor 1
2. System board
1. Optional microprocessor 2
2. System board
1. Rerun the diagnostic test.
2. Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
4. System board.
1. Rerun the diagnostic test
2. Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
4. System board.
1. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
2. System board. Before replacing the system board, ensure that
system board jumper J38 is not installed (the default) when the
error occurs.
1. Update to the latest ROM diagnostic level and retry.