IBM Eserver xSeries 335 Type 8676 Hardware Maintenance Manual And Troubleshooting Manual page 113

Hide thumbs Also See for Eserver xSeries 335 Type 8676:
Table of Contents

Advertisement

Note: See "System" on page 116 to determine which components should be replaced by a field service technician.
Error code/symptom
5962 (IDE CD-ROM drive configuration
error)
8603 (Pointing-device error)
0001200 (Machine check architecture
error)
00012000 (Microprocessor machine
check)
00019501 (Microprocessor 1 is not
functioning - check VRM and
microprocessor LEDs)
00019502 (Microprocessor 2 is not
functioning – check VRM and
microprocessor LEDs)
00019701 (Microprocessor 1 failed)
00019702 (Microprocessor 2 failed)
00180100 (A PCI adapter has requested
memory resources that are not available.)
00180200 (No more I/O space available
for PCI adapter)
00180300 (No more memory (above 1MB
for PCI adapter))
00180400 (No more memory (below 1MB
for PCI adapter))
FRU/action
1. Run the Configuration/Setup Utility program.
2. CD-ROM drive.
3. CD-ROM power cable.
4. IDE cable.
5. System board.
6. Battery.
1. Pointing device
2. System board
1. Microprocessor 1
2. Optional microprocessor 2
3. System board
1. Microprocessor
2. System board
1. Microprocessor 1
2. System board
1. Microprocessor 2
2. System board
1. Microprocessor 1
2. System board
1. Microprocessor 2
2. System board
1. Reorder the adapters in the PCI slots. It is important that your
startup device is positioned early in the startup-device order so
that it is run by POST.
2. Ensure that the PCI adapter and all other adapters are set correctly
in the Configuration/Setup Utility program Utility program. If the
memory resource settings are not correct, change the settings.
3. If all memory resources are being used, you might need to remove
an adapter to make memory available to the PCI adapter. Disabling
the adapter BIOS on the adapter might correct the error. (See the
documentation provided with the adapter.)
1. Run the Configuration/Setup Utility program.
2. Failing adapter.
3. System board.
1. Run the Configuration/Setup Utility program.
2. Failing adapter.
3. System board.
1. Run the Configuration/Setup Utility program.
2. Move the failing adapter to slot 1 or 2.
3. Failing adapter.
4. System board.
Chapter 6. Symptom-to-FRU index
103