(76 mm)
(381 mm)
(102 mm)
Gas line approx. 24" (610 mm)
of flex protruding from
sheet metal box
6' (1,8 m) fan
Gas line
power cord
access
outlet
Valve
Optional
access
fan
panel
Alternate gas line access hole.
12" (305 mm) of flex protruding
from sheet metal box if using
this access hole.
X
Dimensions
33" (838 mm)
24" (610 mm)
3"
3"
15"
(76 mm)
4"
Check that masonry step does not interfere with install dimensions or
vent pipe.
If mantel is combustible, see section following section for allowable
clearances.
A non-combustible hearth is required.
Minimum width of fireplace opening at front: 33-1/4" (855 mm)
Y
X = 15-1/2" (394 mm) minimum
16" (406 mm) if using leveling platform
18-1/2" (470 mm) with fan
Y = 23-1/4" (591 mm)
6' (1.9 m) Fan power cord
Optional fan
3"
(76 mm)
Trim
(sold separately)
Cavity
15"
(381 mm)
10" (254 mm)
23"
(584 mm)
7