How To Enter Heading - Furuno FAR-3210 Operator's Manual

Chart radar
Hide thumbs Also See for FAR-3210:
Table of Contents

Advertisement

1. OPERATIONAL OVERVIEW
1.15

How to Enter Heading

Select manual or automatic heading input as follows:
1. Right-click anywhere in the Sensor information, datum box to show the context-
sensitive menu.
2. Click [Select Sensor] then click [Setting].
3. Use the arrow buttons to select the [HDG] page.
Check for automatic heading input
Manual heading input (not shown on IMO type)
[Gyro Correction] is not shown
when [SYSTEM] is selected in the
[OWN SHIP INFO] - [SENSOR] menu.
[Gyro Correction] is grayed out
when manual heading is in use.
4. For automatic input, follow the procedure below. For manual input, go to
step 5.
1) Check [Sensors].
2) Set the priority for the heading sensors. Click the triangle on any line then se-
lect the sensor to set as the primary source of heading. All other sensors are
then set as secondary source. Only one sensor can be primary while the oth-
ers can be secondary. If a heading sensor is changed from secondary to pri-
mary state and another heading sensor was selected as primary, then that
sensor previously selected to primary state is then automatically selected to
secondary state.
3) Go to step 6.
5. For manual input, check the [Manual] box. Click the heading input box to show
the up and down arrows. Click the arrows to set heading.
6. Click the [OK] button to save the settings then click the [MENU] bar to close the
menu.
1-28
Heading sensor list
Analog gyro heading
GY001
GY002
Gyro Correction
Arrow buttons

Hide quick links:

Advertisement

Table of Contents
loading