1.1 Specifications
Item
Input:
*
Flue Loss Efficiency
Off
Manifold Pressure:
Gas Inlet Supply Pressure:
Orifice Size:
Control Valve:
Shipping Weight:
Chimney:
* The efficiency rating of the appliance is a product thermal efficiency rating determined under continuous
operating conditions and was determined independently of any installed system.
Options:
Standard Remote Control
Deluxe Remote Control
Decorative Bay Window Kit
Decorative Flush Front
Thermostat
Approvals and Installation Codes
Installation must conform to local codes. In the absence of local codes, installation must conform to the
National Fuel Gas Code, ANSI Z233.1 1988, (in the U.S.), or with the current installation code CAN/CGA
B149.1-M86 (in Canada). The appliance, when installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, with the National Electric code ANSI/NFPA No. 70-1990 (in the
U.S.) or with the current CSA C22.1 Canadian Electrical code (in Canada).

Table 1.1 Specifications

Natural Gas (NG)
High
40,000 Btu/Hr (42.2 MJ/Hr)
Low
20,000 Btu/Hr (21.1 MJ/Hr)
:
Fan
3.8" w.c. (0.9 Kpa)
Minimum: 5.0" w.c. (1.2 Kpa)
Normal: 7.0" w.c. (1.7 Kpa)
Maximum: 13.5" w.c. (3.4 Kpa)
31 DMS (.120") (3.05 mm)
Sit 820 Nova
185 Lb. (84 Kg)
Simpson Duravent Model DV-GS
Optional Double-Walled Co-Axial Flex (Max 6 Ft)
31,600 Btu/Hr (31.7 MJ/Hr)
22,500 Btu/Hr (23.7 MJ/Hr)
78.0 %
79.0 %
10.0" w.c. (2.5 Kpa)
Minimum: 11.0" w.c. (2.7
Kpa)
Normal: 13.3" w.c. (3.3 Kpa)
Maximum: 13.5" w.c. (3.4
Kpa)
51 DMS (.067") (1.70 mm)
Single Blower @ 120 cfm
Fibre Brick Panels
Porcelain Panels
Hot Air Ducting Kit
Propane (LPG)
77.0 %
78.5 %