5.2 Refractory Brick Combustion Chamber Panels

For installations where the Refractory Brick panels are to be fitted into the combustion chamber, the following
installation instructions are recommended.

5.2.1 Installation

1. Follow the service instructions in Section 4.4, which describe the step by step procedure to remove the
burner and log set from the combustion chamber. This must be done in advance of the brick panel
installation. Set the burner and logset aside and out of any traffic areas to avoid damage to the log set.
2. Place the bottom edge of the side brick panel into the bottom side corner of the fire-box. Rotate the top
edge of the brick panel up to locate the brick panel flush to side of fire-box. Secure the panel by
screwing one brick panel clip into the hole on the underside of the fire-box baffle. Repeat this for the
opposite panel (see Figure 5.3).
3. Before placing the bottom edge of the rear brick panel into the bottom corner of fire-box, remove the
screws from the upper face of the fire-box rear. Rotate the top edge of the panel towards the back of the
unit until the panel is flush with the back of the fire-box. Locate the " Z" bracket over the top edge of
the brick panel and fasten with the previously removed screws (see Figure 5.3).
4. Re-assemble the unit.
Figure 5.3 –Installation of Refractory Panels