3.2 Installation Of Flooring & Framing
C
: Due to high temperatures, this room heater should be located out of traffic and away from
AUTION
furniture and draperies. Provide a minimum of 48" (1220mm) front clearance to the unit.
Framing the fireplace
1. The fireplace may be installed directly on and/or against standard combustible building materials.
2. The recommended framing dimensions are presented in Figures 3.2 and 3.3. The enclosure for the
fireplace should be framed with standard framing material Please note that the framing height is to the
top of the standoffs; for rear vent applications the framing height 2" above the top of the inlet pipe is
46-1/8" (Figure 3.4).
3. For exterior walls, install a vapour barrier and insulate the enclosure to the same degree as the rest of
the house, or according to local installation codes. In colder climates, if the unit is to be installed
against an exterior wall or chase, insulate the exterior walls according to local installation codes.
For horizontal terminations allow for a minimum of 2" of clearance from the top of the vent to
Note:
combustibles.
Figure 3.1 - Space Requirements