3. Installation

Installation & Safety Notes
Read all instructions before beginning and follow them carefully during installation to ensure maximum
benefit and safety. Failure to follow these instructions will void your warranty and may present a fire hazard.
See the Osburn warranty at the back of this manual for improper installation disclaimers. This fireplace and its
components are certified and safe when installed in accordance with this manual.
W
: Do not connect 120 VAC to the gas control valve or its wiring, as this will damage the valve.
ARNING

Unpacking

The fireplace is packaged with the logs and ember medium inside the firebox. The louvre assemblies and trim
options are separately packaged.
Report to your dealer any parts that may have been damaged in shipment
glass).
Please note: Final installation of the logset/ember and (optional) combustion chamber panels should only be
done after the unit has been completely positioned and framed. It is further recommended that the vent system,
gas line connection, and ideally any electrical servicing requirements be similarly completed before proceeding
with the final placement of the ember medium. Hearth and mantel configurations are also best completed
beforehand. This will prevent accidental jarring and displacement of the ember medium and allow for visual
assessment of the completed package as the consumer will receive it. Trim and louvre kits should be installed
last.

Fireplace Installation

This fireplace is suitable for installation in new construction and wood framed enclosures.
N
: All Installations Require Venting.
OTE

3.1 Locating the Fireplace

The first step for installing the fireplace is to determine the final location of the appliance. The installation
constraints are provided in Figure 3.1 and Table 3.1.

Table 3.1 Minimum Clearances from the Fireplace to Combustible Materials

Glass Front
Floor
48"
* As measured from the bottom of the unit.
Back
0"
0"
(specifically check the condition of the
Top
Ceiling
*
0"
72"
Perpendicular
Wall
12"
/6