3.8 Wiring Connections

Burner Switch
1. If employing additional switches, connect the wiring for the thermostat or the wall switch as noted in item
2 of Section 3.7.
Optional Fan Wiring
Run electrical power to the right side of the appliance, and secure it with a strain relief to the hole provided.
C
: Label all wires prior to disconnection when servicing controls. Wiring errors may cause improper
AUTION
and dangerous poperation. Verify proper operation after servicing.

3.9 Log Set Installation

If optional Fibre Brick Panels or Porcelain Panels are to be installed, do so now, before
I
N
:
MPORTANT
OTE
proceeding with the log set installation. Refer to the Installation and Operation Instructions which accompany
the unit, or to the installation instructions accompanying each kit.
1. Remove the boxed log set and ember medium from within the unit.
2. Open the box and carefully remove the logs.
The log set is comprised of seven individual pieces. These are identified in Figures 3.10 and
Note:
3.11. With the exception of logs F and G, each log has two locating pins. The logs are correctly
positioned when the pins are inserted through the pin holes on the top of the burner tray. Logs F and G
each have two holes on their undersides. These holes are to line up with the pins at the front of the
burner. The logs are secured by pushing each down until they rest on the bottom of the coal grate.
3. Locate the logs to the burner tray in the following order:
(i) log D (face the textured surface to the front)
(ii) log E (position so that the un-charred face of the log is to the right)
(iii) log C (position so that the un-charred face of the log is to the right)
(iv) log B (position so that the un-charred face of the log is to the left)
(v) log A (position so that the charred portion of the log faces towards the rear)
(vi) log F (position so that the un-charred face of the log is to the left)
log G (position so that the un-charred face of the log is to the right)
(vii)
Figure 3.10 – Front View of Log Set
Figure 3.11 – Top View of Log Placement