Operation; Figure 5.11 Wiring Diagram - Osburn Designer DV36 Installation And Operation Instructions Manual

Built-in direct vent gas fireplace designer series
Table of Contents

Advertisement

5. Attach the 4" diameter flexible air duct (supplied in the kit) to the fireplace collar, and run the duct to the
fan housing. N
OTE
length. Use the hose clamps to secure the flex pipe to the fireplace collar and the fan housing collar.
C
AUTION SHOULD BE USED
6. Install the wall switch and cover plate in a convenient location. This switch will control the fan operation.
7. Wire 110V AC service to the junction box and the wall switch. Use the wire nuts to secure the 110 V AC
service wires to the fan wires and then screw the 110V AC ground wire to the fan junction box. See Wiring
Diagram – Figure 4.
The hot air duct kit, when installed, must be electrically grounded in accordance with local codes
N
:
OTE
or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian
Electrical Code, CSA C22.1.
8. Attach the junction box cover to the junction box.
9.Attach the air register to the fan housing.

5.4.2 Operation

Start the fireplace as per the Instruction manual and allow it to warm up.
Turn the wall switch "ON".
M
AINTENANCE
Service and maintain the gas fireplace as per the Instruction manual.
2. Keep the air register(s) clean and free of any
: The air duct has a 1" clearance to combustible construction. Cut the pipe to a suitable
,
AS THE FLEXIBLE PIPE CAN HAVE SHARP EDGES
Figure 5.11 – Wiring Diagram
blockage.
.