Specifications; Features; Intended Use; General Safety - Osburn Designer DV36 Installation And Operation Instructions Manual

Built-in direct vent gas fireplace designer series
Table of Contents

Advertisement

High Altitude Installations
Canada: This appliance has been certified and approved for elevations of up to 4500 feet. For higher elevations
the unit must be de-rated (see section 3.10.3 - Altitude Adjustment)
USA: This appliance should be de-rated 4% for every 1000 feet above 2000 feet above sea level.
1.2

Features

Ignition system:
Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter.
Gas control:
Automatic millivolt powered combination gas control valve with optional remote on/off switch, optional
wall thermostat, and/or optional remote control. The gas valve does not require electricity.
Fan with Variable Speed Control (Optional):
A knob controls the fan speed in connection with a heat sensitive switch, which turns on when the heater
reaches operating temperature. Turning the knob counter-clockwise turns it to the "
Safety controls:
A safety switch will shut the system down in the event of loss of pilot flame.
Outside combustion air supply:
The combustion air supply is obtained entirely from outside the heated living space by the intake of outside
air through the outer portion of the 6-5/8" coaxial double wall vent pipe. Exhaust gases pass through the
inner portion of 4" pipe.

1.3 Intended Use

This appliance is intended to be used as a heater, when installed as a built-in fireplace, according to minimum
requirements as described in detail in the installation instructions. This appliance is suitable for installation in
bedrooms of 2000 cubic feet or more. The appliance is also suitable for retrofit into mobile homes.

1.4 General Safety

The appliance must be properly connected to a venting system in accordance with local codes. This unit must
not be connected to a chimney or flue serving any other appliance.
Operation of this fireplace when not connected to a properly installed and maintained venting
W
:
ARNING
system may result in carbon monoxide poisoning.
Installation and repair should be done by a qualified service person. A professional service technician should
inspect the appliance before use and at least annually. Provide adequate clearances around air openings and
allow accessibility clearance for servicing and proper operation.