Fixed Storage Locations; Fixed Storage Locations; Limited Channel Logout (Hex; Machine Check Interruption Code (Hex E8) - IBM System/370 Operator's Reference Manual

Hide thumbs Also See for System/370:
Table of Contents

Advertisement

FIXED STORAGE LOCATIONS
Area,
Hex
EC
dec,
addr only Function
0-
7
0
Initial program loading PSW, restart new PSW
8- 15
8
Initial program loading CCW1, restart old PSW
16- 23
10
Initial program loading CCW2
24- 31
18
External old PSW
32- 39
20
upervisor Call old PSW
40- 47
28
Program old PSW
48- 55
30
Machine-check old PSW
56- 63
38
Input/output "Id PSW
64- 71
40
Channel status word C.ee diagram)
72- 75
48
Channel address word (0-3 key, 4-7 zeros, 8-31 CCWaddress]
80- 83
50
Interval timer
88- 95
58
External new PSW
96-103
60
Supervisor Call new PSW
104-111
68
Program new PSW
112-119
70
Machine-check new PSW
120-127
78
Input/output
new
PSW
132-133
84
CPU address 8SSQC'd with external intlllTuption, or unchanged
132-133
84
X CPU address assoc'd with external interruption, or zeros
134-135
86
X
External interruption code
136-139
88
X SVC interruption (0-12 zeros,
1~141LC,
15:0, 16-31
code]
140-143
8C
X Program interrupt. (0-12 zeros,
1~141LC,
15:0,16-31
code]
144-147
90
X
Translation exception address (0-7 zeros, 8-31 address]
148-149
94
Monitor class (0-7 zeros, 8-15 class number]
150-151
96
X PER interruption
code
(0-3 code, 4-15 zeros]
152·155
98
X PER address (0-7 zeros, 8-31 address]
156-159
9C
Monitor
code
(0-7 zeros, 8-31 monitor code]
168-171
A8
annelID (0-3type,4-15model,I6-31 max.IOELlength]
172·175
AC
I/O extended logout address (0·7 unused, 8-31 address]
176-179
BO
Limited channel logout (see diagram)
lB5-187
B9
X
I/O address (0-7 zeros, 8-23 address]
216-223
DB
PU timer save area
224-231
EO
lock comparator
save
area
232-239
E8
Machine-check interruption
code
(see
diagram)
248-251
FB
Failing processor storage
address
(0-7 zeros, 8-31 address]
252-255
FC
Region code'
256-351 100
Fixed logout area'
352-383 160
Fl08tin!l"point register
save
area
384-4471180 1
~neral
register
SIMI
area
448-511 lCO
ntrol register
save
area
512t
200
CPU extended logout area (size varies)
'*May vary among modelSj see system library manuals for specifiC model.
tLocation may be chilnged bY programming (bits 8-28 of CR 15 specify address).
5 Channel
6 Main storage control
7 Main storage
8 CPU
9 Channel
10 Main storage control
11 Main storage
12 13
15 16
12 Control unit
16 I nterface address
17·18 Reserved (00)
19 Sequence
code
20 Unit status
21 Cmd. addr. anO key
22 Channel address
23 Device address
23 24
26
2829
31
24-25 Type of termination
00 I nterface disconnect
01 Stop, stack or normal
10
Selective
reset
11 System reset
28(A) I/O error alert
29-31 Sequence
code
MACHINE-CHECK INTERRUPTION CODE
(hex
E81
Page 2·14
Val iditv indicators
MCEL length
55 1
56
24 Fail ing stg. address
25 Region code
27 Floating-pt registers
28 General registers
29 Control registers
30 CPU ext'd logout
31 Storage logical
46 CPU timer
47 Clock comparator
31
63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents