SAS subsystem storage configurations

Several SAS subsystem storage configurations are supported on the 5105-22E, 9008-22L, 9009-22A,
9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-22H, 9223-22S, 9223-42H, or 9223-42S
systems.
The configuration you use depends on the combination of SAS features that you have installed on your
system. The following tables provide an overview of the features and related configurations for the
different systems.
Table 7. SAS subsystem storage configuration for 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, and 9223-22S systems
SAS subsystem
Supported SAS
configuration
RAID adapter
Base function
PCIe3 x8 SAS RAID
storage
internal adapter 6
configuration
Gb (CCIN 57D7)
Base function
Two PCIe3 x8 SAS
storage
RAID internal
configuration
adapters 6 Gb (CCIN
with the split-
57D7)
disk feature
Expanded
One PCIe3 x8 cache
function storage
SAS RAID internal
configuration
adapters 6 Gb (CCIN
57DC)
Table 8. SAS subsystem storage configuration for 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, and 9223-42S systems
SAS subsystem
Supported SAS
configuration
RAID adapter
Base function
PCIe3 x8 SAS RAID
storage
internal adapter 6
configuration
Gb 6 Gb (CCIN
57D7)
Base function
Two PCIe3 x8 SAS
storage
RAID internal
configuration
adapters 6 Gb (CCIN
with the split-
57D7)
disk feature
Expanded
Two PCIe3 x8 cache
function storage
SAS RAID internal
configuration
adapters 6 Gb (CCIN
57D8)
Related information
Serial-attached SCSI cable planning
SAS subsystem service considerations
SAS subsystem base function storage configuration for the 5105-22E, 9008-22L,
9009-22A, 9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-22H, 9223-22S,
9223-42H, or 9223-42S
This configuration uses the base function disk drive backplane.
The base function storage configuration for 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, and
9223-22S systems includes:
• One PCIe3 x8 SAS RAID internal adapter 6 Gb, with RAID 0,10,5,6
• One base function disk drive backplane that supports 8x SFF (2.5") bays
8 Power Systems: SAS subsystem
External SAS
components
SAS port cables
None
None
None
None
One external SAS 4x
Yes
ports that is used for
expansion to external
SAS storage enclosure
FC5887, ESLS, or ESLL
External SAS
components
SAS port cables
None
None
None
None
Two external SAS 4x
Yes
ports that are used for
expansion to external
SAS storage enclosure
(FC 5887, ESLS, or
ESLL)
SAS cables
Limitations
Internal 8x mini SAS HD
cables
Two internal 8x mini SAS
HD cables
Two internal 8x mini SAS
One external SAS storage
HD cables
enclosure (FC 5887,
ESLS, or ESLL) is
supported from the
external SAS port.
SAS cables