16. The bottom of the fan module has slots that slide into tabs located on the
bottom of the server. Align the slots with the tabs and place the fan module.
See Figure 4-82.
17. Slide the fan module to the right when viewed from the front of the server. A
click is heard as the fan module locks into position. Confirm that the release
tab of the fan unit is locked.
18. Connect the FPC cable and fastener. See Figure 4-83.
Figure 4-83. Installing the FPC Cable and Cable Fastener
Note:
connector on the SCSI backplane and the one on the system board.
4-68 Disassembly and Reassembly
Figure 4-82. Install the fan Module
Confirm that the FPC cable is securely connected to the