Using the Command/Response Table for SIS Commands

The command/response table follows this section. Lowercase letters are acceptable
in the command field except where indicated. The table below shows the hexadecimal
equivalent of ASCII characters used in the command/response tables.
space
Figure 19.
Symbols are used throughout the table to represent variables in the command/response
fields. Command and response examples are shown throughout the table.

Symbol Definitions

] = Carriage return with line feed
| or
• = Space
E
NOTE: If unit does not support or recognize the entered commands, nothing will
X!
X@
X#
X$
input lookup tables)
X%
ASCII to HEX Conversion Table
ASCII to Hexadecimal Conversion
}
= Carriage return with no line feed
or W = Escape key
happen and no response is issued.
= Input selection, 1 to 3
= Output selection:
0 = All outputs (Only available for Video Mute)
1 = Output 1 Only (HDMI)
2 = Output 2A Only (HDMI)
3 = Output 2B Only (DTP)
= Input video format:
0 = Auto Detect (Default)
1 = RGB
2 = Auto YUV
3 = RGBcvS
= H/V start — 0 to 255 (default midpoint = 128, translates to the default value in the
= Detected Input Video Format:
0 = No signal present
1 = RGB
2 = Auto YUV
3 = RGBcvS
4 = S-Video
4 = S-Video
5 = Composite
6 = HDMI/DVI
7 = DisplayPort
5 = Composite
6 = DVI
7 = HDMI
8 = DisplayPort