2.
For the Installer

2.4.17 Installing the blower housing on the adapter

– Only for LogWIN with flue connection adapter (accessories)
– First screw the 4 included M8 x 16 hexagon screws into the blower housing from the inside, the attach the
blower housing with seal, 4 nuts and washers to the adapter – Fig. 40.
Fig. 40 Installing the blower housing on the adapter

2.4.18 Installing the lever for cleaning heating surfaces

– Depending on accessibility, either install lever for cleaning heating surfaces on the left or right side. Punch
through the cut-out, insert lever through opening in side panel (Fig. 41) and slide inwards through the cleaning
heating surfaces axle (limit stop must face upwards – Fig. 42) and secure with screws (inserted only) – Fig. 42.
Fig. 41 Punching through the cut-out, inserting lever
for cleaning heating surfaces through opening
Fig. 42 Sliding lever through axle and secur-
ing with screw (inserted only)
22
Limit stop