Dimensional Sketches - Windhager LogWIN Klassik Assembly Instructions Manual

½ m wood gasification boiler; for small and large houses; nominal thermal output: 18, 25, 30 kw
Hide thumbs Also See for LogWIN Klassik:
Table of Contents

Advertisement

4.
For the Service Technician

4.6 Dimensional sketches

Flue gas blower directly on boiler, flue connection at top
All dimensions in mm:
Fig. 70 LogWIN Klassik flue gas blower directly on boiler
Blower housing with adapter, flue connection steplessly adjustable from left to right
All dimensions in mm:
Rear view
108
Fig. 71 LogWIN Klassik flue gas blower with adapter on boiler
Rear view
654
559
277
154
KV
TV
SB
SB
E
KR
227
327
Rear view
Left view
KV . . . . . Boiler feed (5/4" pipe)
KR . . . . . Boiler return (5/4" pipe)
TV . . . . . Thermal valve sensor (1/2" sleeve)
SB . . . . . Thermal safety device (1/2" tube)
E . . . . . Discharge
Left view
30
35
1188
1101
1406