6.10 Reset Factory Defaults

The V-Green 165 user interface has a "Reset to Factory Defaults"
feature to restore the schedule settings back to the original values
programmed at the factory. The user must press and hold the STOP
and OVERRIDE buttons for three (3) seconds to reset the settings back
to factory defaults. All of the UI bar graph LED's will flash three (3) times
to confirm the settings were restored to factory defaults.
7

Priming

The V-Green 165 will always run the PRIMING sequence when starting
from the OFF state, except when starting in OVERRIDE. The factory
Prime settings are 2600 RPM for three (3) minutes.
8

Freeze Protection

The freeze protection function will NOT operate if the START button is not pressed. This
can be confirmed by verifying that the START LED is illuminated.
In the event that the outside air temperature drops below a set threshold,
the V-Green 165 will automatically turn on (assuming the START button
has been pressed) and circulate the pool water. The Freeze Protection
will run according to the following conditions (utilizing the factory default
settings):
Freeze Protection turn ON temperature = 39°F
Freeze Protection Duration = 8 Hours
By utilizing the V-Green 270 user interface (accessory sold separately)
these factory default settings can be changed.
Once this eight (8) hour period has elapsed, the V-Green 165 will check
the ambient temperature again. If the temperature is still below the
set threshold, the V-Green 165 will run for an additional 8 hours. If the
temperature is above the threshold, the V-Green 165 will automatically
return to the 24-hour based schedule.
NOTICE
22