  • Page 1 Installation, Operating, and Service Manual Badu EcoM3 ® Swimming Pool Pump...
  • Page 2: Save These Instructions

    800-223-8538 Phone: 904-739-2626 Fax: 904-737-5261 Web site: www.usa.speck-pumps.com © 2010 All Rights Reserved. Speck Pumps, Jacksonville Florida USA This document is subject to change without notice. Date of Installation: Installed By: Serial Number: For Service Call: SAVE THESE INSTRUCTIONS! 2999999978 - Rev 03/2010...
  • Page 3: Table Of Contents

    Table of Contents Important Safety Instructions General Description Installation Information Preparation Guide ....8 Pump Location ....8 Pipe Sizing .
  • Page 4: Important Safety Instructions

    Important Safety Instructions READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP READ AND FOLLOW ALL INSTRUCTIONS! Important Notice: This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment. WARNING: Before Installing this product, read and follow all warning notices and instructions which are included.
  • Page 5 circulating pump suction line. The centers of the main drains (suction outlets) on any one (1) suction line must be at least three (3) feet apart, center to center. The system must be built to include at least two (2) suction outlets (drains) connected to the pump whenever the pump is running.
  • Page 6 Important Safety Precautions When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS (For all units) WARNING: To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
  • Page 7: General Description

    8 times. The multiple speeds offered by the Badu EcoM3 enables it to run slower and consume less energy but still have the ability to run at full speed if required.
  • Page 8: Installation Information

    NOTE: In Canada, the pump must be located a minimum of three (3) meters (approximately ten (10) feet) from the water (CSA C22.1). 1. Speck Pumps recommends to achieve better self-priming, install the pump as close to the pool as practical. Consult local codes for minimum distance between pool and pump.
  • Page 9: Pipe Sizing

    If the pump is located below water level, isolation valves must be installed on both sides of the pump to prevent the back flow of pool water during any routine or required servicing. The Badu EcoM3 comes equipped with unions on both the suction and discharge ports. This feature simplifies installation and service and eliminates the possibility of leaks at the threaded adaptors.
  • Page 10: Bonding And Grounding

    ETL, CSA) electrical insulating tape. For safety, and to prevent entry of contaminants, reinstall all conduit and terminal box covers. Do not force connections into the conduit box. Table 1.0 Recommended Wire Sizes for the Badu EcoM3 Recommended Wire Sizes For The Badu EcoM3 Distance from Sub-panel...
  • Page 11: Setting Up Remote Control

    (External controller not provided, available through Speck Pumps). This pump can also be plugged into an external controller, such as a time clock, to meet all existing state or local codes. Figure 2: A 3 Channel time clock with potential free contacts. (Also called “dry contacts”) A device using “momentary switches”...
  • Page 12: Operation

    Pressure Test - continued WARNING: When pressure testing the system with water, it is very important to make sure that the pump basket and lid is completely secure. STEPS: 1. Fill the system with water, using care to eliminate trapped air. 2.
  • Page 13: Service And Maintenance

    11. If the pump does not prime and all the instructions to this point have been followed, check for a suction leak. If there is a leak repeat Steps 2 through 6. 12. For technical assistance, call Speck Pumps Technical Support at 800-223-8538. Service and Maintenance...
  • Page 14: Winterizing

    Improper installation and/or operation will void the warranty. The Badu EcoM3 warnings are indicated by a flashing LED light on the control panel. If the error light is on pay attention to the appropriate number of flash intervals of short or long duration, then shut the pump down immediately.
  • Page 15: General Troubleshooting Problems

    Table 2.0 The Badu EcoM3 Warning Sequence Flash Rate LED “Error” Light Error Description Cause 1 Flash Microprocessor failure Microprocessor Start-Up 2 Flashes Low voltage Voltage must exceed < 208V AC control activates itself independently when voltage exceeds 208V for more than six (6) seconds...
  • Page 16: Product Specifications

    Product Specifications PART NUMBER DRAWING NUMBER DESCRIPTION 2921116010 160.1 2921116020 160.2 LOCK RING - LID 2901141201 412.1 O-RING - LID 137 x 5mm 2901114300 BASKET - ONE PIECE 2921110108 CASING 2901158200 CAP - DRAIN (3/8”) WITH GASKET - CASING 2920889410 894.1 LEGO SPACER 2920889420...
  • Page 17: Performance Curves

    Limited Warranty The manufacturer supplies a limited warranty to the original consumer The manufacturer shall not bear any costs or risks incurred in shipping purchaser of the pump and motor on the following terms and condi- a defective pump or motor to the manufacturer or in shipping a repaired tions: or replaced pump or motor to a customer.
  • Page 18 2999999978 - Rev 03/2010 v1...