4. This sequence will then repeat for STEP 2 and then STEP 3 with-
out the V-Green 165 stopping.
5. At the end of STEP 3, the V-Green 165 will wait if necessary for the
completion of the 24-hour schedule. During this waiting period (if
applicable), all of the "active step LEDs" will remain OFF. However,
the START LED will still be illuminated. After completion of the 24
hour schedule, the system restarts at STEP 1 and this cycle will
repeat indefinitely until the user presses the STOP key.
NOTE: Pressing a STEP key other than for the STEP currently running
will cause an immediate transition to the newly selected STEP. The
V-Green 165 will continue with the programmed schedule from that point
forward.
NOTE: If STOP is pressed during normal schedule operation, the 24
hour schedule will stop. When START is pressed again, the 24 hour
schedule will start from STEP 1.
NOTE: If power is lost while the V-Green 165 is running a 24 hour
schedule, upon restoration of power the V-Green 165 will start the 24
hour schedule from STEP 1.
NOTE: If a digital input (provided from an external source) is detected,
the V-Green 165 will start running on the STEP 1, STEP 2, STEP 3, or
OVERRIDE speed corresponding to the digital input. Upon removing
the digital input (provided from an external source), the V-Green 165 will
stop and the user will need to press START to begin the 24 hour sched-
ule operation. However, if START was already pressed prior to receiving
a digital input, then the V-Green 165 will resume running the 24 hour
schedule once the digital input is removed.
NOTE: Pressing STOP at any time turns the V-Green 165 OFF and
clears the start time for the 24 hour schedule.
16