Wiring

The V-Green 165 controller must be wired according to the locally adopted version of the
NEC. A licensed, qualified electrician should complete the wiring for this product. Failure
to comply with this may result in death, serious personal injury or property damage.
The V-Green 165 controller must be wired according to the locally
adopted version of the NEC. A licensed, qualified electrician should
complete the wiring for this product.
The controller is designed to operate with 208-230 Vrms, single phase
power.
The V-Green 165 is designed to handle either a bare wire connection or
a quick disconnect connection. The quick disconnect tab is 0.250" and
will handle any commonly available mating connectors. For a direct wire
connection, the wire insulation should be stripped to a length of approxi-
mately 0.33." The terminal block is capable of handling solid or stranded
wire up to 12 AWG in size. The screw for the mains connections should
be properly tightened to a torque value of 10 in-lb.
Pin #
L1
L2
Green screw
Pin #
J201 - 1
J201 - 2
J201 - 3
J201 - 4
Table 2: Communication Connection
Wire Color
Black
Red or White
Green
Table 1: Mains Connection
Wire Color
Red
Black
Yellow
Green
9
v
Description
Hot 1
Hot 2
Earth
Description
+12V
A
B
COM