Deployment Guide for Maximum Security Environments
Configuring Security Settings in a Web Browser
Using the Maximum Security Profile
Polycom, Inc.
You can configure some of the security settings on the local HDX system
screens. For other security settings, however, you must use the HDX system
web interface.
The Maximum Security Profile lets you control particular fields to meet the
highest security requirements (for example, systems used in government or
military environments). The Security Profile can be set only in the setup
wizard. You can run the setup wizard:
•
At initial setup
•
When you select Erase System Flash Memory during a system update
•
After a system reset when system settings are deleted
After the setup wizard is complete, the Security Profile setting appears as
read-only in the Admin Settings.
To set the Security Profile to Maximum:
>> In the setup wizard, enable Security Mode and set Security Profile to
Maximum.
When you choose this setting, the system automatically sets certain fields to
predefined values. After you set the Security Profile to Maximum in the setup
wizard, some fields are restricted or not configurable. The fields controlled by
the profile are set to predefined values and might have additional restrictions
applied as described in the following tables.
Setup Wizard
Setting
Admin ID
User ID
User Room Password
User Remote Password
Admin Room Password
Admin Remote Password
Restriction
Must be changed.
Must be changed.
Must be entered.
Must be entered.
Must be changed.
Must be changed.
7
Need help?
Do you have a question about the HDX Systems and is the answer not in the manual?
Questions and answers