Perfection In 50 Hz Mode Alignment - Sony PDW-HD1500 Maintenance Manual

Professional disc recorder
Hide thumbs Also See for PDW-HD1500:
Table of Contents

Advertisement

Output Level Adjustment
1. Enter the maintenance mode.
2. Select A20: VPR VR as follows:
Maintenance mode → M1: ADJUST → A2: AUDIO/
VIDEO/BATTERY → A20: VPR VR → VIDEO
OUT LEVEL
3. Connect the analog composite waveform monitor to
each VIDEO OUTPUT COMPOSITE connector, then
check the white peak level. If the signal amplitude A is
not within the specification, adjust it.
m
. The outputs of VIDEO OUTPUT COMPOSITE 1
and 2 connectors cannot be adjusted separately.
. When checking/adjusting the output of VIDEO
OUTPUT COMPOSITE 2 (SUPER) connector,
change the connection of the video monitor as
Connection 2 on the previous page.
. The menu picture of the maintenance mode is
superimposed in the output of VIDEO OUTPUT
COMPOSITE 2 (SUPER) connector. If the superim-
posed picture obstructs, set the HOME CHAR SEL
of function menu page to OFF. (Be sure to reset it to
ON after checking/adjusting.)
Output channel
Adjustment point
(A20 : VPR VR)
[Connection 1]
COMPOSITE 1
VIDEO OUT LEVEL
[Connection 2]
COMPOSITE 2
B
4. To exit A20: VPR VR, press the [RETURN] button
once.
PDW-HD1500/V1 (E)
Saving the Data (Saving the adjustment data)
When the adjustment is not performed in step 3, skip over
to step 5.
5. Enter A2F: NV-RAM CONTROL, then execute
"SAVE ALL ADJUST DATA".
. Message "Save Complete" will be displayed on the
menu screen when this data saving is completed
normally.
n
To cancel saving of adjusted data and recover it to
previous condition, execute "ALL DATA PREVI-
OUS".
6. Exit the maintenance mode.

8-4-6. Perfection in 50 Hz Mode Alignment

1. Switch the operation mode to the standard mode with
the setup menu ITEM-013.
Setup menu
ITEM-013
(SYSTEM FREQUENCY SELECT)
2. Reset the switches and function menu settings to the
customer setting. (Refer to Section 8-4-2.)
Specification
B = 700 ± 7 mV
Mode
8 59.94 Hz
8-9

Hide quick links: